3 BASIC FUNCTION
3.1 Outline of servo parameter and object dictionary
107
3
The following is an example of the servo parameter number PA01 with the setting values of "FEDCBA98" in hexadecimal.
When setting a servo parameter with one particular digit
When setting a servo parameter using a combination of several digits
For example, if the servo parameter name is "Function selection A-1", the setting digit name is "Forced stop deceleration
function selection", and the setting digit is the fourth last digit in PA04, the servo parameter is expressed as shown below.
[Pr. PA04.3 Forced stop deceleration function selection]
Servo
parameter
Symbol Name Outline
PA04.3 *AOP1 Forced stop deceleration function
selection
Set "Forced stop deceleration function" to enabled/disabled.
Initial value: 1h (enabled)
[Pr. PA01] =
PA01.0 = "8"
PA01.1 = "9"
PA01.2 = "A"
PA01.3 = "B"
PA01.4 = "C"
PA01.5 = "D"
CDBFAE89
PA01.6 = "E"
PA01.7 = "F"
Detail No.
[Pr. PA01] =
PA01.0-1 = "98"
PA01.2-4 = "CBA"
PA01.5 = "D"
CDBFAE89
PA01.6 = "E"
PA01.7 = "F"
Detail No.