3 BASIC FUNCTION
3.5 Stroke limit function [G]
119
3
System configuration example
[Pr. PA14 Travel direction selection] = "0" (CCW or the positive direction)
Set LSP (Upper stroke end) for the limit signal that suppresses the operation in CCW or the positive direction. The on/off
status of LSP (Forward rotation stroke end) is output as FLS (Upper stroke limit) to the controller, and the on/off status of LSN
(Reverse rotation stroke end) is output as RLS (Lower stroke limit).
[Pr. PA14 Travel direction selection] = "1" (CW or the negative direction)
This example shows a case where CCW or the positive direction of the servo amplifier is different from the positioning
address increasing direction of the controller. The on/off status of LSN (Reverse rotation stroke end) is output as FLS (Upper
stroke limit) to the controller, and the on/off status of LSP (Forward rotation stroke end) is output as RLS (Lower stroke limit).
CN3-12
FLS
RLS
LSP
LSN
CN3-2
Controller Servo amplifier
Movable range
Limit switch Limit switch
Moving
part
CCW or positive direction
Positioning address increasing direction
CN3-12
FLS
RLS
LSP
LSN
CN3-2
Controller Servo amplifier
Movable range
Limit switch Limit switch
Moving
part
CCW or positive direction
Positioning address increasing direction