4 APPLICABLE FUNCTIONS
4.20 Disconnection/incorrect wiring detection function
373
4
Setting method [G] [B]
When [Pr. PC19.4 Output open-phase detection selection] is set to "1" (enabled), the output open-phase detection function
will be enabled.
Setting method [A]
When [Pr. PC26.4 Output open-phase detection selection] is set to "1" (enabled), the output open-phase detection function
will be enabled.
Servo
parameter
Symbol Name Outline
PC19.4 *COP6 Output open-phase detection selection Enable or disable the detection of output open-phase detection function.
0: Disabled (initial value)
1: Enabled
PC19.6 *COP6 Output open phase - Judgment speed
selection
Select the judgment speed of the output open-phase detection function.
0: Servo motor speed (initial value)
1: Speed command
In the torque control, set "0" (servo motor speed). When "1" (speed command) is set,
[AL. 139.2 Output open-phase error] does not occur.
Servo
parameter
Symbol Name Outline
PC26.4 *COP5 Output open-phase detection selection Enable or disable the detection of output open-phase detection function.
0: Disabled (initial value)
1: Enabled
PC26.6 *COP5 Output open phase - Judgment speed
selection
Select the judgment speed of the output open-phase detection function.
0: Servo motor speed (initial value)
1: Speed command
In the torque control, set "0" (servo motor speed). When "1" (speed command) is set,
[AL. 139.2 Output open-phase error] does not occur.