Do you have a question about the Mitsubishi Electric MU-07RV and is the answer not in the manual?
Brand | Mitsubishi Electric |
---|---|
Model | MU-07RV |
Category | Air Conditioner |
Language | English |
Details about SW2 addition and settings for Auto Restart Function.
Removal of the Sleep Mode function.
Addition of the ECONO COOL operation feature.
SWING button removed; Vane Control available.
Change in outdoor model names for MU, MUH, and MXZ series.
Identification and functions of components within the indoor unit.
Identification and functions of components within the outdoor unit.
Table showing indoor unit combinations for MXZ-18RV.
Table showing indoor unit combinations for MXZ-32RV.
Specifications for MSC-07RV, MSC-09RV, MSC-12RV indoor units.
Specifications for MU-07RV, MU-09RV, MU-12RV outdoor units.
Specifications for MSC-07RV, MSC-09RV indoor units.
Specifications for MUX-10RV, MUX-18RV, MUX-24RV outdoor units.
Specifications for MSC-07RV, MSC-09RV, MSC-12RV when used in multi systems.
Specifications for MXZ-18RV and MXZ-32RV outdoor units.
Noise criteria curves for MSC-07RV, MSC-09RV, MSC-12RV indoor units.
Noise criteria curves for MU-07RV, MU-09RV, MU-12RV outdoor units.
Noise criteria curves for MUH-07RV, MUH-09RV, MUH-12RV outdoor units.
Noise criteria curves for MUX-10RV, MUX-18RV outdoor units.
Noise criteria curves for MUX-24RV outdoor unit.
Noise criteria curves for MXZ-18RV and MXZ-32RV outdoor units.
Outline and dimensions of MSC-07RV, MSC-09RV, MSC-12RV indoor units.
Outline and dimensions of MU-07RV, MU-09RV, MU-12RV outdoor units.
Outline and dimensions of MUX-10RV, MUX-18RV outdoor units.
Outline and dimensions of MUX-24RV outdoor unit.
Outline and dimensions of MXZ-18RV outdoor unit.
Outline and dimensions of MXZ-32RV outdoor unit.
Wiring diagram for MSC-07RV, MSC-09RV, MSC-12RV indoor units.
Wiring diagrams for MU-07RV, MU-09RV, MU-12RV outdoor units.
Wiring diagrams for MUH-07RV, MUH-09RV, MUH-12RV outdoor units.
Wiring diagram for MUX-10RV outdoor unit.
Wiring diagram for MUX-18RV outdoor unit.
Wiring diagram for MUX-24RV outdoor unit.
Wiring diagram for MXZ-18RV outdoor unit.
Wiring diagram for MXZ-32RV outdoor unit.
Refrigerant system diagram for MSC-07RV, MSC-09RV, MSC-12RV indoor units.
Refrigerant system diagram for MU-07RV, MU-09RV, MU-12RV outdoor units.
Refrigerant system diagrams for MSC/MUH series units.
Refrigerant system diagrams for MUX series units.
Refrigerant system diagrams for MXZ-18RV and MXZ-32RV units.
Performance curves for indoor units showing capacity and input.
Performance curves for outdoor units showing capacity and input.
Performance curves for single indoor/outdoor unit combinations.
Performance curves for outdoor low pressure and current in COOL mode.
Performance curves for outdoor low pressure and current.
Performance data tables for cooling operation at 220V.
Performance data tables for cooling operation at 240V.
Performance data tables for heating operation at 220V.
Explanation of wireless remote controller functions and buttons.
Explanation of the operation indicator lamp on the indoor unit.
Operation details for COOL mode, including fan speed and frost prevention.
Operation details for DRY mode, including fan speed and compressor control.
Operation details for FAN mode, only indoor fan operates.
Operation details for HEAT mode, including fan speed and cold air prevention.
Operation mode for personalized comfort control based on room temperature.
Control of fan motor speed using rotational frequency feedback.
Automatic control of horizontal vane angle for optimal air distribution.
Procedure for forcing defrosting mode for service purposes.
Changing defrost interval time and temperature settings.
Shortening timer operation intervals for service.
Modifying PC boards for individual indoor unit operation.
Switching between MU and MUH types and setting auto-restart function.
General precautions and checks before starting troubleshooting.
Steps to follow when diagnosing issues using indicator lamps and charts.
Procedure for replacing remote controller batteries and resetting.
Flowcharts for troubleshooting common operational issues.
Table of indoor unit symptoms, detection methods, and check points.
Table of outdoor unit symptoms, detection methods, and check points.
Check method and criterion for room temperature thermistor.
Check method and criterion for indoor coil thermistor.
Check method and criterion for indoor fan motor.
Check method and criterion for vane motor.
Check method and criterion for defrost thermistor.
Check method and criterion for compressor.
Check method and criterion for outdoor fan motor.
Check method and criterion for linear expansion valve.
Check method and criterion for pressure switches and compressor thermistor.
Block diagram showing the system organization of MXZ-18RV.
Block diagram showing the system organization of MXZ-32RV.
Control logic for linear expansion valve (LEV).
Control logic based on the number of operating indoor units.
Rules for selecting operation mode in multi-systems.
Outdoor fan control based on compressor status and protection.
Compressor operational frequency range for cooling and heating.
Defrosting conditions and details during heating operation.
Protection mechanisms against high and low pressure.
Protection against high discharge temperature.
Refrigerant recovery process during heating operation.
Table relating sensors to their purpose and actuators.
Step-by-step instructions for removing the front panel of the indoor unit.
Instructions for removing the electronic and display P.C. boards from the indoor unit.
Steps for removing the electrical box from the indoor unit.
Instructions for removing the vane motor from the indoor unit.
Steps for removing the line flow fan and indoor fan motor.
Instructions for disassembling MU series outdoor units.
Instructions for disassembling MUH series outdoor units.
Instructions for disassembling MUX-10RV outdoor unit.
Instructions for disassembling MUX-18RV outdoor unit.
Instructions for disassembling MUX-24RV outdoor unit.
Instructions for disassembling MXZ-18RV outdoor unit.
Instructions for disassembling MXZ-32RV outdoor unit.
List of structural parts for MSC-07RV, MSC-09RV, MSC-12RV indoor units.
List of accessory parts, including remote controller holder.
List of electrical parts for MSC-07RV, MSC-09RV, MSC-12RV indoor units.
List of parts for indoor unit heat exchangers.
List of structural parts for MU-07RV, MU-09RV, MU-12RV outdoor units.
List of structural parts for MUH-07RV, MUH-09RV, MUH-12RV outdoor units.
List of functional and electrical parts for MUH outdoor units.
List of functional and electrical parts for MUX-10RV outdoor unit.
List of functional, electrical, and structural parts for MUX-18RV outdoor unit.
List of functional and electrical parts for MUX-24RV outdoor unit.
List of structural parts for MUX-24RV outdoor unit.
List of electrical parts for MXZ-18RV outdoor unit.
List of functional parts for MXZ-18RV outdoor unit.
List of electrical parts for MXZ-32RV outdoor unit.
List of structural parts for MXZ-32RV outdoor unit.
List of functional parts for MXZ-32RV outdoor unit.
List of parts for the remote controller.
List of accessory parts like drain sockets.
Information on the air cleaning filter, its function, and maintenance.
Information on the deodorizing filter, its cleaning, and replacement.
Selection guide for different-diameter pipes for multi-systems.
Information on the outlet guide for changing air discharge direction.