SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ····································4
2. PART NAMES AND FUNCTIONS······················8
3. SPECIFICATION·················································9
4. NOISE CRITERIA CURVES ·····························11
5. OUTLINES AND DIMENSIONS ·······················12
6. WIRING DIAGRAM ··········································13
7. REFRIGERANT SYSTEM DIAGRAM··············19
8. PERFORMANCE CURVES······························21
9. ACTUATOR CONTROL····································29
10. SERVICE FUNCTIONS·····································30
11. TROUBLESHOOTING······································30
12. DISASSEMBLY INSTRUCTIONS·····················51
13. PARTS LIST······················································54
14. RoHS PARTS LIST···········································58
Wireless type
Models
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
MUZ-GA25VA -
MUZ-GA25VA -
MUZ-GA25VA -
MUZ-GA25VA -
MUZ-GA35VA -
MUZ-GA35VA -
MUZ-GA25VAH -
MUZ-GA25VAH -
MUZ-GA25VAH -
MUZ-GA25VAH -
MUZ-GA35VAH -
MUZ-GA35VAH -
E2
E1
E4
E3
E2
E1
E2
E1
E4
E3
E2
E1
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
For servicing of RoHS compliant products, refer to the RoHS Parts List.
HFC
utilized
R410A
Please void OB379 REVISED EDITION-B.
No. OB379
REVISED EDITION-C
Revision:C
MUZ-GA25VA(H)- has been added.
E4
OUTDOOR UNIT
Indoor unit service manual
MSZ-GAVA Series (OB378)
MSZ-CBVA Series (OB441)
OB379 C--1qxp 07.2.1 2:25 PM Page 1
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MUZ-GA25VA and is the answer not in the manual?

Mitsubishi Electric MUZ-GA25VA Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Seasonal Energy Efficiency Ratio (SEER)6.1
Power Supply230V/1Ph/50Hz
RefrigerantR410A
Outdoor Unit Dimensions (HxWxD)550 x 800 x 285 mm
Weight (Indoor Unit)9 kg
Outdoor Unit Dimensions (W x H x D)800 x 550 x 285 mm
Indoor Unit Weight9 kg
TypeAir Conditioner

Summary

Technical Changes

Part Names and Functions

Specification

Wiring Diagram

Refrigerant System Diagram

Performance Curves

Capacity and Input Curves

Graphs showing cooling capacity and total input based on indoor/outdoor temperatures.

Actuator Control

Troubleshooting

Troubleshooting Cautions

Important safety and handling precautions before performing troubleshooting.

Failure Mode Recall Function

How to recall and interpret memorized fault codes for diagnosis.

Troubleshooting Instruction Flowchart

Step-by-step guide to diagnose issues based on LED indications.

Troubleshooting Check Table

Table correlating LED indications with abnormal points and conditions.

Trouble Criterion of Main Parts

Specifications for testing main electrical components like thermistors and motors.

Troubleshooting Flowcharts

Detailed diagnostic flows for specific failure modes like inverter issues.

Test Point Diagram and Voltage

Diagrams showing test points and voltage specifications on the inverter and power PC boards.