This Installation Manual describes only for the outdoor unit and the connected
indoor unit of MSC series.
If the connected indoor unit is MSH, MSZ, MCFH, SLZ and SEZ series, refer to
the Installation Manual for MSH, MSZ, MCFH, SLZ and SEZ series for the infor-
mation other than outdoor unit.
INSTALLATION MANUAL
FOR INSTALLER
CONTENTS
1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR
SAFETY ........................................................................................... 2
2. INSTALLATION DIAGRAM & ACCESSORIES ................................ 2
3. SELECTING THE INSTALLATION LOCATION ............................... 3
4. OUTDOOR UNIT INSTALLATION ................................................... 4
5. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND
TEST RUN ....................................................................................... 6
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Dansk
Svenska
Türkçe
SPLIT-TYPE AIR CONDITIONER
Model MXZ-A26/32WV
HFC
utilized
R410A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MXZ-A26/32WV and is the answer not in the manual?

Mitsubishi Electric MXZ-A26/32WV Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMXZ-A26/32WV
CategoryAir Conditioner
LanguageEnglish

Summary

General Safety Precautions

Installation Diagram and Accessories

Selecting the Installation Location

Indoor Unit Installation Constraints

Specifies constraints for connecting indoor units to the outdoor unit.

Outdoor Unit Installation

Installing the Outdoor Unit

Instructions for securely mounting the outdoor unit and ensuring proper foundation.

Drain Socket Mounting

Procedure for attaching the drain socket to the outdoor unit for drainage.

Service Panel and Connect Cover Removal

Steps for accessing internal components by removing the service panel and connect cover.

Indoor/Outdoor Wiring and Power Connection

Connection Finishing and Test Run

Flared Connections

Guidelines for pipe length, height difference, and refrigerant adjustment.

Selecting Pipe Size

Table matching indoor/outdoor unit models with required pipe sizes.

Piping Preparation

Specifications for commercially available copper pipes and insulation.

Flaring Work Procedures

Step-by-step guide for performing flaring work correctly to prevent leaks.

Flaring Work Details

Details on using flaring tools and comparing results for proper flare execution.

Flaring Work Check

Visual inspection of flared work to ensure it meets quality standards.

Pipe Connection Procedure

Instructions for connecting pipes to indoor and outdoor units, including tightening torques.

Purging Procedures and Leak Test

Steps for evacuating the system and checking for refrigerant leaks.

Earthing Work

Procedure for grounding the unit according to electrical installation standards.

Post-Installation Checks

Checklist of items to verify after completing the installation process.

Refrigerant Gas Charge

Instructions for charging the correct amount of refrigerant into the unit.

Test Run Procedure

Steps for performing a functional test run of the installed air conditioner.

Customer Explanation

Guidance on explaining unit operation and maintenance to the end-user.

Related product manuals