Do you have a question about the Mitsubishi Electric MXZ30TN2 and is the answer not in the manual?
Compares model differences for USA and Canada regarding defrosting and temperature settings.
Details the "I FEEL CONTROL" feature of the remote controller for precise temperature setting.
Describes the automatic restart feature after a power outage, resuming previous operation mode.
Identifies and describes the components of the indoor unit.
Identifies and describes the components of the outdoor unit.
Details the parts and functions of the wireless remote controller.
Specifies the operational temperature and humidity limits for cooling and heating.
Details the maximum allowable lengths for refrigerant piping between indoor and outdoor units.
Provides performance data for cooling capacity under various conditions.
Presents graphical representations of cooling and heating performance characteristics.
Lists standard operating data for electrical, refrigerant, and unit specifications.
Provides overall dimensions and outlines for the indoor unit.
Provides overall dimensions and outlines for the outdoor unit.
Displays the wiring diagrams for the MSH09TW indoor and MUH09TW outdoor units.
Shows the wiring diagrams for the MXZ30TN/MXZ30TN2 outdoor units.
Explains the operation and buttons of the wireless remote controller.
Details the "I FEEL CONTROL" operation, including temperature settings and operation logic.
Provides instructions for operating the unit in COOL mode.
Provides important precautions and checks to perform before troubleshooting.
Provides a flowchart for troubleshooting various operational issues and their causes.
A table outlining abnormal symptoms, detection methods, and check points for troubleshooting.
Provides step-by-step instructions for disassembling the MSH09TW indoor unit.
Details disassembly procedures for MXZ30TN/MXZ30TN2 outdoor units.
Lists structural parts for the MSH09TW indoor unit.
Illustrates and lists parts for MUH09/12TN outdoor units.
Provides details on optional refrigerant pipes and their specifications.
Lists optional different-diameter pipes for connecting units with varying pipe sizes.
| Series | MXZ |
|---|---|
| Cooling Capacity | 30, 000 BTU/H |
| HSPF | Up to 10.0 |
| Voltage | 208/230V |
| Refrigerant | R410A |
| Indoor Unit Noise Level | Varies by indoor unit model |
| Indoor Unit Dimensions (WxHxD) | Varies by indoor unit model |
| Indoor Unit Weight | Varies by indoor unit model |
| Type | Multi-Zone Heat Pump |