Do you have a question about the Mitsubishi Electric PUHZ-SW50VHA and is the answer not in the manual?
Heating Capacity | 16.0 kW |
---|---|
Refrigerant | R410A |
Dimensions (Outdoor Unit) | 943 x 950 x 330 mm |
Weight (Outdoor Unit) | 72 kg |
EER (Cooling) | 3.04 W/W |
COP (Heating) | 4.0 |
Details model service reference changes and the addition of an Energy Monitor function.
Lists indoor unit service manuals for various models with their corresponding manual numbers.
Essential safety rule to disconnect power before accessing terminals.
Specific safety guidelines for R410A refrigerant, including piping preparation and tool usage.
Precautions for reusing R22 pipes, pipe thickness, flare dimensions, and specific R410A tools.
Installation guidelines for salt-proof models to maintain performance, especially near coastal areas.
Details the chargeless system and its advantages for installation and unit reliability.
Information on refrigerant charge amounts based on piping length and compressor technical specifications.
Power wiring specifications for outdoor units, including circuit rating and wire size requirements.
Summary of self-diagnosis check codes and actions for recurring or non-recurring troubles.
Detailed table linking check codes to specific faults and recommended service actions.
Step-by-step procedures for removing major components of the outdoor unit.
Visual guides illustrating the process of disassembling and removing various parts.