How to fix a serial communication error on a Mitsubishi Electric PURY-RP200?
- GGail LittleSep 5, 2025
To address a serial communication error on your Mitsubishi Electric Air Conditioner, check the wiring and connections for any damage.
How to fix a serial communication error on a Mitsubishi Electric PURY-RP200?
To address a serial communication error on your Mitsubishi Electric Air Conditioner, check the wiring and connections for any damage.
What to do if my Mitsubishi Electric PURY-RP200 Air Conditioner has a heatsink overheat protection error?
If your Mitsubishi Electric Air Conditioner shows a heatsink overheat protection error, check the heatsink for dust accumulation and clean it.
What to do if my Mitsubishi Electric PURY-RP200 Air Conditioner displays a temperature sensor fault?
If your Mitsubishi Electric Air Conditioner displays a temperature sensor fault, replace the faulty temperature sensor.
What to do if my Mitsubishi Electric Air Conditioner displays a transmission power supply fault?
If your Mitsubishi Electric Air Conditioner displays a transmission power supply fault, ensure power is being supplied to the unit.
What to do if my Mitsubishi Electric PURY-RP200 shows a water supply cutoff?
If your Mitsubishi Electric Air Conditioner indicates a water supply cutoff, ensure that the water supply is turned on.
What to do if my Mitsubishi Electric Air Conditioner displays a power supply signal sync error?
If your Mitsubishi Electric Air Conditioner displays a power supply signal sync error, verify the synchronization settings.
Brand | Mitsubishi Electric |
---|---|
Model | PURY-RP200 |
Category | Air Conditioner |
Language | English |
Covers essential checks and procedures before servicing the refrigerant cycle.
Lists tools and materials required for installation and servicing, categorizing them for R410A use.
Details on wiring work, control wiring, and maximum allowable cable lengths for different systems.
Procedures for group settings and interlock settings with LOSSNAY units using the ME remote controller.
Detailed electrical wiring diagram for PURY-RP200, RP250, RP300YJM-A outdoor units.
Schematic diagrams of the refrigerant circuit for outdoor units and BC controllers.
Explains functions and factory settings of dipswitches on the outdoor unit control board (SWU, SW1, SW2, SW3, SW4, SW5).
Describes control methods, initial control, start-up control, and bypass control for outdoor units.
Details on controlling solenoid valves (SVA, SVB, SVC, SVM1, SVM2) and LEV based on operation modes.
Checklist of essential items before performing a test run, including refrigerant leaks and insulation resistance.
Step-by-step guide on how to perform a test run using the MA remote controller.
Identifies symptoms of over/undercharging and guides on adjusting refrigerant amount.
Procedures for entering and operating the refrigerant amount adjustment mode.
Comprehensive list of error codes, their definitions, and the units where they occur.
Guides on how to respond to error displays on the remote controller, including troubleshooting steps.
Procedures for identifying and repairing refrigerant leaks in indoor and outdoor units.