Models PUHY-P200, P250, P300, P350, P400YGM-A
PUHY-P450, P500, P550, P600, P650YGM-A
PUY-P200, P250, P300, P350YGM-A
Service Handbook
AIR CONDITIONERS CITY MULTI

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PUY-P200 and is the answer not in the manual?

Mitsubishi Electric PUY-P200 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUY-P200
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Warning : Carefully read the labels affixed to the main unit.

Emphasizes reading all unit labels for safety.

Before installing the unit, be sure to carefully read all of the following safety precautions.

Stresses the importance of reading all safety precautions before installation.

Precautions for Handling Units for Use with R410A

Do not use the existing refrigerant piping

Warns against using old refrigerant piping with R410A systems.

Use refrigerant pipes made of C1220 phosphorus deoxidized copper...

Specifies approved materials and conditions for refrigerant piping.

Use a vacuum pump with a reverse-flow-check valve.

Recommends specific vacuum pump equipment for R410A.

Before Installing the Unit

Warning

General warning before installation.

Do not use a charging cylinder.

Warns against using charging cylinders with R410A.

Only use R410A refrigerant.

Emphasizes using only R410A refrigerant.

Use liquid refrigerant to charge the system.

Recommends charging with liquid refrigerant.

Before Installing (Relocating) the Unit or Performing Electric Work

Do not spray water on the air conditioners or immerse the air conditioners in water.

Warns against water contact with the unit due to electric shock risk.

Use wires that are specified in the installation manual.

Emphasizes using specified wiring to prevent electrical hazards.

Ground the unit.

Details proper grounding procedures and warnings.

Before the Test Run

Caution

General caution before initiating a test run.

Do not operate the unit without panels and safety guards in their proper places.

Emphasizes operating the unit only with panels and guards installed.

Do not operate switches with wet hands to avoid electric shock.

Advises against operating switches with wet hands.

1 Read Before Servicing

5 Electrical Wiring Diagram

6 Refrigerant Circuit

[1] Refrigerant Circuit Diagram

Illustrates the refrigerant flow for various models.

8 Test Run

[4] Adjustment and Judgment of Refrigerant Amount

Guides on adjusting and judging the refrigerant amount.

[5] Refrigerant Volume Adjustment Mode Operation

Details the process for adjusting refrigerant volume.

9 Troubleshooting

[1] Check Code List

A comprehensive list of error codes and their meanings.

[2] Responding to Error Display on the Remote Controller

Provides guidance on addressing remote controller error displays.

[4] Troubleshooting of Principal Parts

Detailed troubleshooting for major components.

[5] Refrigerant Leak

Procedures for locating and repairing refrigerant leaks.