Español
INSTALLATION MANUAL
For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
Air-Conditioners
PUZ-A
·NHA, PUZ-A·NHA-BS
PUY-A
·NHA, PUY-A·NHA-BS
FOR INSTALLER
PARA EL INSTALADOR
BG79U896H02_cover 06.5.18, 11:091
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PUZ-A·NHA and is the answer not in the manual?

Mitsubishi Electric PUZ-A·NHA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUZ-A·NHA
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Before Electric Work

Essential steps and precautions to follow before performing any electrical installation work.

R410A Refrigerant Usage

Specific guidelines and precautions for using R410A refrigerant with the air conditioning system.

Installing the Outdoor Unit

Foundation Specifications

Details on the required foundation, bolts, concrete thickness, and weight-bearing capacity for secure mounting.

Installing the Refrigerant Piping

R410A Refrigerant Piping Precautions

Safety and material precautions when installing refrigerant pipes for R410A systems.

Connecting Refrigerant Pipes

Step-by-step guide for connecting refrigerant pipes, including insulation, flare nut tightening, and leak checks.

Refrigerant Piping Installation

Detailed procedure for connecting refrigerant piping, covering service panel removal and stop valve operation.