SERVICE MANUAL
No.OCH708
SPLIT-TYPE AIR CONDITIONERS
R32
December 2018
Outdoor unit
[Model Name]
PUZ-SM100VKA
PUZ-SM125VKA
PUZ-SM140VKA
PUZ-SM100YKA
PUZ-SM125YKA
PUZ-SM140YKA
[Service Ref.]
PUZ-SM100VKA.TH
PUZ-SM125VKA.TH
PUZ-SM140VKA.TH
PUZ-SM100YKA.TH
PUZ-SM125YKA.TH
PUZ-SM140YKA.TH
PARTS CATALOG (OCB708)
CONTENTS
1. REFERENCE MANUAL ································· 2
2. SAFETY PRECAUTION ································· 2
3. SPECIFICATIONS ········································ 12
4. DATA ····························································· 13
5. OUTLINES AND DIMENSIONS ··················· 16
6. WIRING DIAGRAM ······································ 17
7. WIRING SPECIFICATIONS ·························· 20
8.
REFRIGERANT SYSTEM DIAGRAM
············· 25
9. TROUBLESHOOTING ································· 27
10. FUNCTION SETTING ··································· 84
11.
MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER
····90
12. EASY MAINTENANCE FUNCTION ··········· 100
13. DISASSEMBLY PROCEDURE ··················· 104

Questions and Answers:

Mitsubishi Electric PUZ-SM100VKA.TH Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUZ-SM100VKA.TH
CategoryAir Conditioner
LanguageEnglish

Summary

2 SAFETY PRECAUTION

2-1. ALWAYS OBSERVE FOR SAFETY

Emphasizes disconnecting power before accessing terminals.

2-2. CAUTIONS RELATED TO NEW REFRIGERANT

Details specific cautions for R32 refrigerant.

[1] Warning for service

Provides general warnings for servicing and installation procedures.

[2] Cautions for service

Lists cautions to be observed during service operations.

[3] Additional refrigerant charge

Details procedures for adding refrigerant.

[4] Cautions for unit using R32 refrigerant

Specific cautions for units using R32 refrigerant.

2-3. PRECAUTIONS WHEN REUSING EXISTING R22/R410A REFRIGERANT PIPES

Precautions for reusing existing refrigerant pipes.

3 SPECIFICATIONS

4 DATA

5 OUTLINES AND DIMENSIONS

6 WIRING DIAGRAM

7 WIRING SPECIFICATIONS

8 REFRIGERANT SYSTEM DIAGRAM

8-1. REFRIGERANT COLLECTING (PUMP DOWN)

Procedure for collecting refrigerant (pump down) before relocation or disposal.

9 TROUBLESHOOTING

9-1. TROUBLESHOOTING

Overview of troubleshooting based on check codes and reoccurrence.

9-3. HOW TO PROCEED "SELF-DIAGNOSIS"

Steps for initiating and performing self-diagnosis.

9-3-1. Self-diagnosis <PAR-3xMAA>

Self-diagnosis procedure for a specific remote controller model.

9-3-2. Remote controller check <PAR-3xMAA>

How to check the remote controller's functionality.

9-3-3. Self-diagnosis <PAR-21MAA>

Self-diagnosis procedure for another remote controller model.

9-3-4. Self-Diagnosis During Maintenance or Service <PAR-21MAA>

Performing self-diagnosis during maintenance.

9-3-5. Remote controller check <PAR-21MAA>

Checking remote controller functionality for a specific model.

9-3-6. Self-diagnosis <Wireless remote controller>

Self-diagnosis procedure for wireless remote controllers.

9-4. SELF-DIAGNOSIS ACTION TABLE

Table linking check codes to causes and actions.

9-5. TROUBLESHOOTING OF PROBLEMS

Troubleshooting common phenomena and their causes.

10 FUNCTION SETTING

11 MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER

12 EASY MAINTENANCE FUNCTION

13 DISASSEMBLY PROCEDURE