4.5 Check code
Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH.
D
n+1
= D
1
XOR D
2
XOR D
3
XOR ,,, D
n
XOR: Exclusive OR
Following is an example of a Check code (BCC) calculation.
Check code (BCC) D
17
= D
1
xor D
2
xor D
3
xor … xor D
14
xor D
15
xor D
16
= 30h xor 41h xor 30h xor 45h xor 30h xor 41h
xor 02h xor 30h xor 30h xor 31h xor 30h xor 30h
xor 30h xor 36h xor 34h xor 03h
= 77h
4.6 Delimiter
Packet delimiter code; ASCII CR(0Dh).
Header Message
Check code
Delimiter
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
SOH D
0
Reserved D
1
Destination D
2
Source D
3
Type D
4
Length D
5
STX D
6
Data D
7
| |
| |
ETX D
n
Check code D
n+1
P P P P P P P P
Header Message
SOH Reserved
Destination
Address
Source
Address
Message
type
Message length STX
OP code
page
OP code
Set Value ETX
Check
code
(BCC)
Delimiter
01 30 41 30 45 30 41 02 30 30 31 30 30 30 36 34 03 77 0D
D
0
D
1
D
2
D
3
D
4
D
5
D
6
D
7
D
8
D
9
D
10
D
11
D
12
D
13
D
14
D
15
D
16
D
17
D
18
Header Message Check code
Delimiter

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric RS232/485/LAN Serial Communication Control and is the answer not in the manual?

Mitsubishi Electric RS232/485/LAN Serial Communication Control Specifications

General IconGeneral
BrandMitsubishi Electric
ModelRS232/485/LAN Serial Communication Control
CategoryMonitor
LanguageEnglish

Related product manuals