EasyManuals Logo

Mitsubishi Electric SEH Series User Manual

Mitsubishi Electric SEH Series
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
CCopyright 2002 MITSUBISHI ELECTRIC ENGINEERING CO., LTD.
Reprinted in Feb. 2004 No. OC281 REVISED EDITION-B PDF 25
Distributed in May 2003 No. OC281 REVISED EDITION-B 224
Reprinted in Mar. 2003 No. OC281 REVISED EDITION-A 10
Distributed in Jan. 2003 No. OC281 REVISED EDITION-A PDF 241
Reprinted in Jul. 2002 No. OC281 10
Distributed in May 2002 No. OC281 PDF 807
Made in Japan.
New publication, effective May 2003.
Specifications subject to change without notice.
OPTIONAL PARTS
12
1. REFRIGERANT PIPES
The air conditioner has flared connections its indoor and outdoor sides.
Please use the optional extension pipe as follows.
3. AIR FILTER
Applied unit
SEH-1.6AR.TH, SEH-1.6AR1.TH
SEH-2AR.TH
SEH-2.5AR.TH
SE-1.6AR.TH, SE-1.6AR1.TH
SE-2AR.TH
SE-2.5AR.TH
SE-1.6AR.TH-T, SE-1.6AR1.TH-T
SE-2AR.TH-T
SE-2.5AR.TH-T
Models
PAC - 1000 FT
Applied unit
SEH-1.6AR.TH
SEH-1.6AR1.TH
SE-1.6AR.TH
SE-1.6AR1.TH
SE-1.6AR.TH-T
SE-1.6AR1.TH-T
SEH-2AR.TH
SE-2AR.TH
SE-2AR.TH-T
Models Pipe length
Pipe size O.D.mm (in.)
Cross-section A-Gas
{12.7
(1/2)
{15.88
(5/8)
{6.35
(1/4)
{27
{31
{21
{27
0
150 ((45))
400 ((120))
0
150 ((45))
400 ((120))
B-liquid
Insulation
CD
3m
5m
7m
10m
15m
3m
5m
7m
10m
15m
MAC-680PI
MAC-681PI
MAC-682PI
MAC-683PI
MAC-684PI
MAC-670PI
MAC-671PI
MAC-672PI
MAC-673PI
MAC-674PI
Additional
refrigerant
charge
R-22(g)
SEH-2.5AR.TH
SE-2.5AR.TH
SE-2.5AR.TH-T
0
195 ((45))
520 ((120))
3m
5m
7m
10m
15m
MAC-860PI
MAC-861PI
MAC-862PI
MAC-863PI
MAC-864PI
{9.52
(3/8)
2. REMOTE CONTROLLER EXTENSION CABLE
When installing the remote controller at a distance from the air conditioner, use the designated extension cable with connec-
tor.
Part No.
Length
PAC-905EC
12m
PAC-906EC
20m
PAC-918EC
30m
PAC-919EC
50m
The values in double parentheses show the quantities of
additional refrigerant charge for SE- • AR.TH and SE- • AR.TH-T.
OC281-B-4.qxp 04.2.10 2:24 PM Page 94

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric SEH Series and is the answer not in the manual?

Mitsubishi Electric SEH Series Specifications

General IconGeneral
BrandMitsubishi Electric
ModelSEH Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals