Screen Display (Home screen) - Icons Screen Display (Home screen) - Icons
[LOSSNAY group]
During operation
While the unit is stopped
Fan speed
[General equipment group]
During operation
While the unit is stopped
General equipment icon
Room temperature:
Displays the current room temperature.
The displayed temperature will blink when the room
temperature is at or above 104ºF (40ºC) (102ºF (39ºC) on
some models), or at or below 32ºF (0ºC) (46ºF (8ºC) on
some models).
When multiple air conditioning units (indoor units) are
registered to a group, current indoor temperature on the
main indoor unit is displayed.
Water temperature:
Display ranges 32-199ºF (0-93ºC). When the temperature
is beyond the range, 32ºF (0ºC) or 199ºF (93ºC) will blink
on the display. When multiple Air To Water (PWFY) units
are registered to a group, current water temperature on the
main Air To Water (PWFY) unit is displayed.
When the Temperature Correction function is enabled:
When the Temperature Correction function is enabled, the
corrected temperature will appear in the green outline font.
Interlocked ventilation (LOSSNAY):
Displays the operation status of the ventilation that is
interlocked with the air conditioning (indoor) units.
General equipment icon:
Displays the General equipment type.
GROUP screen
[Air conditioning unit group • Air To Water (PWFY) group]
During operation
Group No.
Mode
Unit icon
Hold
Scheduled operation
HOLD-ON
HOLD-OFF
Error
Startup (communication)
error
Filter sign*
Check Water sign**
Energy-saving
Interlocked ventilation (LOSSNAY)*
Fan speed*
Air direction*
Louver*
Room temperature
Group name
Set temperature
Set temperature
Water temperature
[Air To Water (PWFY) group]
Setback and Auto (dual set point) modes
Set cooling/heating set
temperature
Remaining OVERRIDE
time
While the unit is stopped
Interlocked ventilation*
(LOSSNAY)
*: Displayed only on Air conditioning unit groups and when the selected unit supports the function
**: Displayed only on Air To Water (PWFY) groups
Error:
Displays
when an error occurs.
Startup (communication) error:
Displays
as well as the error display when a startup
(communication) error occurs.
Filter sign:
Displays
when filter needs maintenance.
During scheduled operation:
Displays
during scheduled operation.
Energy saving:
will appear on the screen while energy-save control is
being performed. (depending on the indoor unit model)
When the Hold function is enabled or Timer execution is
prohibited:
Displays
.
Note : While the icon is displayed on the button, the operation is locked.