Service
'19 HM-T-340
E51 - Inverter and fan motor error (for FDCW60VNX)
YES
YES
NO
NO
Isn’t F
2
fuse (250V, 50A) blown?
Check soldered surfaces on the
outdoor unit control PCB for foreign
material like dust, fouling, etc.
Replace fuse.
Replace the control PCB.
Remove foreign material.