Type | Split System |
---|---|
Cooling Capacity | 3.5 kW |
Heating Capacity | 4.0 kW |
Refrigerant | R32 |
Weight (Indoor Unit) | 10 kg |
Power Supply | 220-240V, 50Hz |
Energy Efficiency Ratio (Cooling) | 3.21 |
Indoor Unit Weight | 10 kg |
Noise Level (Indoor Unit) | 21 dB(A) |
Noise Level (Outdoor Unit) | 47 dB(A) |
Details dimensions and features of indoor units for various models.
Details dimensions and features of outdoor units for various models.
Overview of wireless and wired remote controller dimensions and features.
Wiring diagrams and component identification for indoor units.
Wiring diagrams and component identification for outdoor units.
Sound pressure level graphs for indoor and outdoor units of SRK25ZJ-S.
Sound pressure level graphs for indoor and outdoor units of SRK35ZJ-S.
Sound pressure level graphs for indoor and outdoor units of SRK20ZJX-S.
Sound pressure level graphs for indoor and outdoor units of SRK25ZJX-S.
Sound pressure level graphs for indoor and outdoor units of SRK35ZJX-S.
Diagram illustrating refrigerant piping for SRK25ZJ-S/SRC25ZJ-SA.
Diagram illustrating refrigerant piping for SRK35ZJ-S/SRC35ZJ-SA.
Diagram illustrating refrigerant piping for SRK20/25/35ZJX-S/SRC20/25/35ZJX-SA.
Details operating temperature ranges, piping lengths, and selection criteria.
Cooling and heating capacity data based on airflow and temperature conditions.
Cooling and heating capacity data based on airflow and temperature conditions.
Cooling and heating capacity data based on airflow and temperature conditions.
Cooling and heating capacity data based on airflow and temperature conditions.
Cooling and heating capacity data based on airflow and temperature conditions.
Detailed instructions and safety precautions for installing the indoor unit.
Detailed instructions and safety precautions for installing the outdoor unit.
Guidelines for proper installation and usage of refrigerant piping.
Procedures for selecting appropriate refrigerant pipe sizes based on unit specifications.
Guidelines for performing refrigerant piping work, including flaring and bending.
Explains how to control unit functions using the remote controller.
Describes the function of the unit's ON/OFF button for manual operation.
Details the auto restart feature that restores previous settings after power interruption.
Instructions for modifying settings to prevent interference with multiple remote controllers.
Explains how to adjust flap and louver direction for optimal air distribution.
Describes the automatic control of airflow direction for efficient room conditioning.
Details setting the ON/OFF timers and sleep timer for convenience.
Instructions for setting the indoor unit's installation location for optimal airflow.
Explains the operation of key components and control patterns during heating.
Explains the operation of key components and control patterns during cooling.
Describes how the unit determines operation mode based on temperatures.
Details various protective functions to prevent damage and ensure safe operation.
Explains the conditions and operation of the defrost heater during heating.
Safety precautions and initial checks before performing maintenance.
Step-by-step guide for diagnosing and fixing issues when the unit does not operate.
Guide for diagnosing and fixing issues when the unit runs but has problems.
Table mapping error codes to causes and symptoms for self-diagnosis.
Instructions on accessing and using the service mode for diagnostics.
Detailed inspection steps for various troubleshooting scenarios.
Procedures for checking indoor electrical components like PCB and fan motor.
Key inspection points for the outdoor unit.
Instructions for installing the wired remote controller.
Details on installing the interface kit for connectivity.
Information on installing the Super link E board for advanced control.