EasyManua.ls Logo

Mitsubishi A1SD75P2-S3 - 5.1.7 Types and Roles of Monitor Data

Mitsubishi A1SD75P2-S3
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 11
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
5.1.7 Types and roles of monitor data
Data that indicates the positioning system's operation state is stored in the buffer
memory's monitor data area.
When using the positioning system, this data must be monitored as necessary.
The data that can be monitored is shown below.
Monitoring the system
Monitors the AD75 specifications, such as the module name and OS type, and the
operation history. (System monitor data
Md.1 to Md.28 )
Monitoring the axis operation state
Monitors the data related to the operating axis, such as the current position and
speed. (Axis monitor data
Md.29 to Md.56 )
* The axis monitor data is updated every 56.8ms. Note that "
Md.32 Valid M code"
is updated simultaneously when "M code ON signal [XD, XE, XF] turns ON.
(1) Monitoring the system
Monitoring the AD75 specifications
Monitor details Corresponding item
Monitor the module name
Md.2
Module name
Monitor the OS type
Md.3
OS type
Monitor the OS version
Md.4
OS version
Md.5
Clock data (Hour: minute)
Monitor the clock data used in the system
Md.6
Clock data (Second: 100ms)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com