5 - 36
MELSEC-
5 DATA USED FOR POSITIONING CONTROL
5.2.4 Detailed parameters 2
Setting value, setting range
Setting value buffer
memory address
Item
Value set with peripheral device
Value set with
sequence program
Default
value
Axis 1 Axis 2 Axis 3
Pr.26
Acceleration time 1
36
37
186
187
336
337
Pr.27
Acceleration time 2
38
39
188
189
338
339
Pr.28
Acceleration time 3
40
41
190
191
340
341
Pr.29
Deceleration time 1
42
43
192
193
342
343
Pr.30
Deceleration time 2
44
45
194
195
344
345
Pr.31
Deceleration time 3
The setting value range differs according to the "
Pr.25
Size selection for acceleration/deceleration time" setting.
Here, the value within the [Table 1] range is set.
[Table 1] on right page
1000
46
47
196
197
346
347
Pr.32
JOG speed limit
value
The setting value range differs depending on the "
Pr.11
Stepping motor mode selection" or "
Pr.1
Unit setting".
Here, the value within the [Table 2] range is set.
[Table 2] on right page
20000
48
49
198
199
348
349
0 :
Pr.8
Acceleration time 0
0
1 :
Pr.26
Acceleration time 1
1
2 :
Pr.27
Acceleration time 2
2
Pr.33
JOG operation
acceleration time
selection
3 :
Pr.28
Acceleration time 3
3
0 50 200 350
0 :
Pr.9
Deceleration time 0
0
1 :
Pr.29
Deceleration time 1
1
2 :
Pr.30
Deceleration time 2
2
Pr.34
JOG operation
deceleration time
selection
3 :
Pr.31
Deceleration time 3
3
0 51 201 351
Pr.26
Acceleration time 1 to
Pr.28
Acceleration time 3
Set the item to reach "
Pr.7 Speed limit value" from speed 0 during positioning
operation.
The setting value size is determined by "
Pr.25 Size selection for
acceleration/deceleration time".
Pr.29
Deceleration time 1 to
Pr.31
Deceleration time 3
Set the item to reach speed 0 from "
Pr.7 Speed limit value" during positioning
operation.
The setting value size is determined by "
Pr.25 Size selection for
acceleration/deceleration time".
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com