5 - 122
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
Cd.32
Interrupt request during
continuous operation
•
To interrupt the operation during continuous operation, set "1".
•
If the interrupt request is received after setting "1", "0" will be automatically stored
by the OS.
•
When changing the acceleration time during speed change, set the new
acceleration time.
Pr.25
setting
Cd.33
setting range (unit)
1-word type 0 to 65535 (mm)
2-word type 0 to 8388608 (ms)
Cd.33
New acceleration time value
•
When changing the deceleration time during speed change, set the new
deceleration time.
Pr.25
setting
Cd.33
setting range (unit)
1-word type 0 to 65535 (mm)
2-word type 0 to 8388608 (ms)
Cd.34
New deceleration time value
Cd.35
Acceleration/deceleration
time change during speed
change, enable/disable
selection
•
Set whether to enable/disable the acceleration/deceleration time change during
speed change.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com