11 - 16
MELSEC-A
11 MANUAL CONTROL
When the "JOG start signal" is turned ON immediately after the stop signal
OFF (within 56.8ms)
When the "JOG start signal" is turned ON immediately after the stop signal OFF
(within 56.8ms), it will be ignored and the JOG operation will not be carried out.
ON
Axis stop signal
[Y13, Y14, Y1C]
OFF
ON
OFF
56.8
ms
A JOG start signal OFF
ON while the stop signal is
ON will be ignored.
Forward run JOG operation
Forward run JOG start signal
[Y16, Y18, Y1A]
Fig. 11.10 Operation when the JOG start signal is turned ON immediately after the stop signal OFF