- 1-9 -
ENGLISH
x : Available
MOIRE CANCEL LEVEL XX
CLAMP PULSE POSITION
X
FACTORY PRESET ---
HORIZ-CONVERGENCE
XXX
VERT-CONVERGENCE XXX
FACTORY PRESET ---
DEGAUSS ---
POWER SAVE XXX
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
CONTROL LOCK X
OSD POSITION XXX
OSD TURN OFF XXX
DIAGNOSIS ---
LANGUAGE X
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
AUTO SAVE X
ALL RESET ---
FACTORY PRESET ---
Group
Icon
Press the Minus Button
Item
Item
Icon
Press the Plus Button
To adjust the horizontal beam alignment on the full screen area.
To adjust the vertical beam alignment on the full screen area.
To decrease the level of the moire-clear wave.
To eliminate an excessive green or white-back ground that may occur
when external sync signals are applied to the monitor.
To restore to factory preset level.
To restore to factory preset level.
To eliminate possible color shading
or impurity due to magnetic effects.
To select the constant power
consumption mode.
To select the power-save mode.
(Your computer must be set for power
management.)
To permit all OSD adjustments.
To lock the OSD function except
for "BRIGHT" and "CONTRAST".
To move the OSD screen position
in a clockwise direction.
To save the new setting with a
confirmation message.
Restores all items to the factory preset level.
(PURITY)
(CONVER.)
(MISC.)
To clamp the video signal at the
front of the H-Sync pulse.
"BRIGHT" and "CONTRAST" are unavailable at the locked condition.
When selecting "OFF", if "SAVE" is not done before the OSD screen disappeared, the new setting is invalid.
To choose the language used on OSD.
ENG.....English, FRA.....French, ESP.....Spanish, GER.....German, JPN.....Japanese
To save the new setting automati-
cally.
To restore to factory preset level.
C
BA
To clamp the video signal at the
back of the H-Sync pulse. If you
connect to an older Macintosh, you
may need to press plus button.
To adjust the time that the OSD screen disappear when no access.
Indicates the current scanning frequency, factory or user preset timing
number, and signal input connector.
To move the OSD screen position
in a counter clockwise direction.
A. Press "FACTORY PRESET" to restore to the factory preset level.
B. Press and buttons together, to restore to the factory preset level.
C. Set data does not change by the change of the signal timing.
If a non-Factory Preset timing is used, "FACTORY PRESET" does not work.
- +
- +
-
+
Downloaded from ManualMonitor.com Manuals