EasyManua.ls Logo

Mitsubishi FR-BU2-1.5K - Page 36

Mitsubishi FR-BU2-1.5K
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
WIRING
(5) When connecting the FR-BEL power factor improving DC reactor,
the brake unit terminal P/+ must be connected to the inverter.
Accidental connection to P1 terminal may damage the brake unit.
(6) When connecting several FR-BU2 to the inverter, be sure to connect
terminal P/+, N/- of the brake unit to terminal P/+, N/- of the inverter.
Do not pass wires from terminal P/+ and N/- of the brake unit to
terminals of other brake unit.
FR-BU2
Inverter
FR-BEL
P1
P/+
N/-
Correct connection Wrong connection
N/- P/+ PR
FR-BU2
Inverter
FR-BEL
P1
P/+
N/-
N/- P/+ PR
FR-BU2
Inverter
P/+
N/-
Correct connection Wrong connection
N/-
P/+
FR-BU2
N/-
P/+
FR-BU2
Inverter
P/+
N/-
N/-
P/+
FR-BU2
N/-
P/+

Table of Contents