7.
SElTlNG
PARAMSTERS
BEPORE
B'IXFtTuP
L
~
r
Callk.t*lg
the
Fmqqurnoy
Yan
I
Calibrate Me frequency meter
before
statling operation
so
that the output status can
be
monitored correctly. When
the
parameter unit is
used,
the frequency meter can be
I
calibrated oreciselv. (Refer
11
If
an inverter which has been
used
before
is
to
be
used, the set values
01
the parameters
might have been changed according to a
specific
operation. Therefore, it
is
necessary
to
initialize
the
parameter set values before starting the operation. The ten initialize refers
to
the
operation to reset the parameter values
to
the factory-setting values.
The parameter unit can be
used
to
initialize the parameter set values. (Refer
to
page 39
for details of initialization procdure.)
Remember that the following parameters cannot
be
initialized by the parameter clear opera-
tion using the parameter unit. For these parameters, change the parameter set value
to
the
required value after reading the current setting, or reset the parameters
to
the factory-set-
ting by the aU clear operation.
e
Pr.900
'FM
terminal calibration' Pr.905 "Gain for frequency setting current"
Pr.902 'Bias for frequency setting voltage' Pr.38 "Frequency at
5V
(IOV)
input"
Pr.903 "Gain for frequency setting voltage' Pr.39 'Frequency at 20 mA input"
e
Pr.904 gias for frequency setting current" Pr.75 "Reset selectiorddetection
of
parameter unit disconnection"
-
20
-
L