31
PERFORMANCE DATA
HEAT operation(220V)
MCFH-13NV - : MUCFH-13NV -
E4E4
HEAT operation(240V)
MCFH-13NV - : MUCFH-13NV -
E4E4
HEAT operation(240V)
MCFH-24NV - : MUCFH-24NV -
E3E3
HEAT operation(220V)
MCFH-24NV - : MUCFH-24NV -
E3E3
HEAT operation(240V)
MCFH-18NV - : MUCFH-18NV -
E3E3
HEAT operation(220V)
MCFH-18NV - : MUCFH-18NV -
E3E3
CAPACITY :4.0(KW) INPUT :1130(W)
OUTDOOR WB(:)
INDOOR
-10 -5 0 5 10 15 20
DB(:)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 2.52 735 3.04 881 3.56 994 4.08 1074 4.60 1141 5.08 1175 5.60 1198
21 2.40 791 2.88 938 3.40 1040 3.88 1119 4.40 1175 4.88 1209 5.38 1254
26 2.16 848 2.68 994 3.16 1096 3.68 1175 4.20 1232 4.68 1266 5.20 1300
CAPACITY :4.0(KW) INPUT :1220(W)
OUTDOOR WB(:)
INDOOR
-10 -5 0 5 10 15 20
DB(:)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 2.52 793 3.04 952 3.56 1074 4.08 1159 4.60 1232 5.08 1269 5.60 1293
21 2.40 854 2.88 1013 3.40 1122 3.88 1208 4.40 1269 4.88 1305 5.38 1354
26 2.16 915 2.68 1074 3.16 1183 3.68 1269 4.20 1330 4.68 1366 5.20 1403
CAPACITY :5.4(KW) INPUT :1910(W)
OUTDOOR WB(:)
INDOOR
-10 -5 0 5 10 15 20
DB(:)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 3.40 1242 4.10 1490 4.81 1681 5.51 1815 6.21 1929 6.86 1986 7.56 2025
21 3.24 1337 3.89 1585 4.59 1757 5.24 1891 5.94 1986 6.59 2044 7.26 2120
26 2.92 1433 3.62 1681 4.27 1853 4.97 1986 5.67 2082 6.32 2139 7.02 2197
CAPACITY :5.4(KW) INPUT :2010(W)
OUTDOOR WB(:)
INDOOR
-10 -5 0 5 10 15 20
DB(:)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 3.40 1307 4.10 1568 4.81 1769 5.51 1910 6.21 2030 6.86 2090 7.56 2131
21 3.24 1407 3.89 1668 4.59 1849 5.24 1990 5.94 2090 6.59 2151 7.26 2231
26 2.92 1508 3.62 1769 4.27 1950 4.97 2090 5.67 2191 6.32 2251 7.02 2312
CAPACITY :6.2(KW) INPUT :2540(W)
OUTDOOR WB(:)
INDOOR
-10 -5 0 5 10 15 20
DB(:)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 3.91 1651 4.71 1981 5.52 2235 6.32 2413 7.13 2565 7.87 2642 8.68 2692
21 3.72 1778 4.46 2108 5.27 2337 6.01 2515 6.82 2642 7.56 2718 8.34 2819
26 3.35 1905 4.15 2235 4.90 2464 5.70 2642 6.51 2769 7.25 2845 8.06 2921
CAPACITY :6.2(KW) INPUT :2650(W)
OUTDOOR WB(:)
INDOOR
-10 -5 0 5 10 15 20
DB(:)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 3.91 1723 4.71 2067 5.52 2332 6.32 2518 7.13 2677 7.87 2756 8.68 2809
21 3.72 1855 4.46 2200 5.27 2438 6.01 2624 6.82 2756 7.56 2836 8.34 2942
26 3.35 1988 4.15 2332 4.90 2571 5.70 2756 6.51 2889 7.25 2968 8.06 3048