6 Drying inside
1. Controls
(a) Prevents the growth of mildew by drying the moisture accumulated on the heat exchanger when the dehumidifier is
OFF.
(b) Drying inside operation does not depend on having a full water level.
(c) The following operations are performed during drying inside operation.
2. Start conditions for drying inside operations
(a) Automatic drying inside mode - This mode starts when the Drying inside button is set to ON, and any of the following
conditions are met.
• The Power button is turned OFF.
• The OFF timer time is reached.
• The LAUNDRY mode completes operations.
(b) Manual drying inside mode - This mode starts when the Drying inside button is operated while the following condition
is met.
• The Power button is turned OFF.
3. Operating details
(a) The following indications are displayed during DRYING INSIDE operation
• LED indicator: Only mildew guard elite lamp flashes, others off
• LCD panel: All off
(b) Drying inside operates according to the following steps
• Step 1: Moisture is allowed to drip from the heat exchanger. The louvre is positioned upwards at 90˚.
• Step 2: Moisture on the heat exchanger is dried with air.
• Step 3: Moisture on the heat exchanger is dried with heat.
• Step 4: The heat exchanger is cooled if the temperature rises too high.
• Step 5: Internal humidity is discharged in Step 4, and the louvre moves to the closed position.
(c) Step 3 does not perform the tube temperature or room temperature check that accompanies a microprocessor reset,
and jumps directly to Step 5.
(d) Mechanisms operated in the above steps (* are deemed E
2
PROM data.)
(e) Drying inside operation does not stop even if tank full is detected.
4. Conditions for drying inside operation to end
(a) Upon completion of step 5 above.
(b) The following buttons terminate drying inside operation (during steps 1 to 5 above) when pressed.
• Power button
• Drying inside button
• ON timer button
(c) The following operations are performed when drying inside ends.
5. Drying inside operation is not performed under the following conditions.
(a) The power is ON.
(b) The ON timer is operating.
(c) An error is detected during self-diagnosis.
Target part Compressor Airflow fan
Solenoid valve
Louvre
Operation ON/OFF Rank control OFF Stops at 90°