15
8-7. SMART SET ( ) OPERATION
1. How to SET SMART SET operation
(1) Press OPERATE/STOP (ON/OFF) button.
(2) Select COOL, HEAT or ECONO COOL mode.
(3) Press SMART SET button.
(4) Set the temperature, fan speed, and airfl ow direction for SMART SET operation.
NOTE: • SMART SET operation cannot be selected during DRY or AUTO mode operation.
• The setting range of HEAT mode in SMART SET operation is 50°F (10°C) and 61 - 88°F (16 - 31°C).
• 2 settings can be saved. (One for COOL/ECONO COOL, one for HEAT)
2. How to cancel operation
• Press SMART SET button again.
• SMART SET operation can also be cancelled by pressing OPERATION SELECT button to change the operation mode.
The same setting is selected from the next time by simply pressing SMART SET button.
8-8. EMERGENCY/TEST OPERATION
In the case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the right side of the
indoor unit. Emergency operation is available when the remote controller is missing or has failed, or when the batteries of
the remote controller are running down. The unit will start and OPERATION INDICATOR lamp will light up.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan runs at High
speed and the temperature control does not work.
After 30 minutes of test run operation, the system shifts to EMERGENCY COOL/HEAT MODE with a set temperature of
75°F (24°C). The fan speed shifts to Med.
The coil frost prevention works even in the test run or the emergency operation.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO (
) mode.
Emergency operation continues until EMERGENCY OPERATION switch is pressed once/ twice or the unit receives any
signal from the remote controller. In the latter case, normal operation will start.
NOTE: Do not press EMERGENCY OPERATION switch during normal operation.
8-9. Changing temperature indication (°F/°C)
EMERGENCY OPERATION switch
E.O.
SW
• The following indication does not depend on the
shape of lamp.
Press once <Cool>
Press again <Heat>
Press once again <Stop>
OPERATION INDICATOR lamp
Lighted
Not lighted
Operation mode COOL HEAT
Set temperature 24°C 24°C
Fan speed Med. Med.
Horizontal vane Auto Auto
• The preset unit is °F.
• °F → °C: Press RESET button while the temperature
buttons are pressed.
• °C → °F: Press RESET button or remove the batteries .
Press RESET button gently using