FOR USER
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
English
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para
garantizar un uso seguro y correcto.
PARA EL USUARIO
Español
MANUEL D’UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du
climatiseur.
POUR L’UTILISATEUR
Français
SPLIT-SYSTEM HEAT PUMP
PKA-A·HA7
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Mr. Slim PKA-A-HA7 and is the answer not in the manual?

Mitsubishi Mr. Slim PKA-A-HA7 Specifications

General IconGeneral
BrandMitsubishi
ModelMr. Slim PKA-A-HA7
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions and Warnings

Symbols Used in Text

Explains symbols used in the text for warnings and cautions regarding safety.

Symbols Used in Illustrations

Illustrates symbols indicating grounding requirements for unit parts.

General Safety Warnings and Cautions

Provides crucial warnings and cautions for safe operation and installation to prevent injury, death, or unit damage.

Unit Disposal Guidelines

Instructions on consulting a dealer for proper disposal of the air conditioning unit.

Parts Identification

Indoor Unit Components

Details the components of the indoor unit, including fan speed, vane, louver, and filter.

Remote Controller Types

Distinguishes between wired and IR wireless remote controllers for the air conditioner.

Wired Remote Controller Interface

Illustrates the interface and function buttons of the wired remote controller.

Wired Remote Controller Function Buttons

Explains the function of each button on the wired remote controller, like ON/OFF, SELECT, RETURN, MENU.

Remote Controller Display and Icons

Display Modes and Icons

Details the Full and Basic display modes and explains various icons shown on the remote controller display.

Remote Display Icons Explained

Explains the meaning of various icons displayed on the remote control, such as operation mode, fan speed, and timer.

Remote Controller and Outdoor Unit Details

IR Wireless Remote Controller Information

Provides detailed information on the IR remote controller's display, buttons, usage notes, and signal reception.

Battery Installation and Replacement

Guides on how to install and replace batteries in the remote controller.

Outdoor Unit Overview

Illustrates the outdoor unit, including its service panel and connections.

Basic Operation Procedures

Turning Unit ON and OFF

Details the procedure for turning the air conditioner unit ON and OFF using wired and IR wireless remote controllers.

Operation Settings Overview

Covers operation status memory, settable temperature ranges, and mode selection.

Operation Mode Selection

Explains how to select operation modes like Cool, Dry, Fan, Auto, and Heat using the remote controller.

Blinking Mode Icon Meaning

Explains the meaning of a blinking mode icon, indicating shared operation with other units.

Advanced Operation Settings

Temperature Setting Adjustment

Details how to adjust the temperature setting using the [F2] and [F3] buttons on the remote controller.

Fan Speed Adjustment

Guides on adjusting the fan speed using the [F4] button or the fan speed button.

Automatic Fan Speed Setting (IR Remote)

Details the procedure for setting automatic fan speed using the IR wireless remote controller.

Airflow Up/Down Direction Setting

Describes how to navigate the menu to access and set the airflow's up/down direction (vane setting).

Operation Menu Navigation and Controls

Menu Navigation and Settings

Guides on navigating menus, saving settings, exiting screens, and accessing Vane-Vent (Lossnay) options.

Ventilation and Vane Control

Details ventilation settings for LOSSNAY units and available vane control options like Auto, Step, and Swing.

Manual Airflow Left/Right Direction

Describes the manual method to adjust the louver's left/right direction when the button is not used.

Additional Operation Features

Airflow and Ventilation Control

Explains changing airflow direction via IR remote and ventilation patterns for LOSSNAY units.

Timer Function Overview

States that timer functions differ by remote controller type.

Emergency Operation Procedure and Modes

Details the procedure and modes for emergency operation when the IR wireless remote controller is unusable.

Filter Information and Reset

Explains how to check filter status, reset the filter sign, and where to find cleaning instructions.

Care and Cleaning Procedures

Filter and Unit Cleaning

Provides comprehensive instructions and cautions for cleaning air filters and the unit's exterior.

Common Operational Issues

Addresses common problems like poor heating/cooling, airflow issues, and delayed warm air during heating.

Troubleshooting Common Problems

Airflow, Sound, and Vapor Issues

Addresses airflow direction problems, unusual operational sounds, and room odors or white mist/vapor.

Water Emission, Display Errors, and Start/Stop Problems

Covers water dripping, remote controller display errors, and issues with starting or stopping the unit.

Timer, System Control, and Error Codes

Explains timer and central control problems, as well as error codes and protection device activation.

Noise and Remote Display Issues

Addresses loud noise issues and problems with the IR wireless remote controller's display or signal reception.

Technical Specifications

Dry Mode Temperature Change Explanation

Explains the automatic change of set temperature when entering Dry mode.

Technical Specifications Overview

Presents a comprehensive overview of technical specifications including model, power, electrical ratings, dimensions, airflow, and noise.