6
Indoor model
Function
Indoor unit power supply
Air flow(Hi)
Power outlet
Running current
Power input
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level (Hi)
Fan speed (Hi)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Outdoor model
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R-407C)
Refrigerating oil (Model)
Thermistor
RT61(at0:)
K /h
A
A
W
%
A
A
"
mm
kg
dB
rpm
k"
k"
kW
R/h
K /h
A
A
W
A(kW)
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k"
MSH-C18SV -
E1
Single phase
220-230V,50Hz
756
15
0.25
55
100.0-95.7
0.25
RA4V27-EF
WHT-BLK 184
BLK-RED 250
1,015O320O190
14
5
42
1,180
4
10
10
MUH-C18SV -
E1
2,142-2,196
15
55
0.39
PE-36VPEHT
1,600
C-R 1.06
C-S 2.03
RA6V50-OG
WHT-BLK 116
BLK-RED 111
850o605o290
54
52
810-828
1
1.70
1100 (NEO22)
33.18
Cooling
5.1
2.5
9.44-9.34
2,035-2,085
98.0-97.1
9.05-8.95
2.44-2.38
Heating
5.4
9.17-9.12
1,975-2,035
97.9-97.0
8.78-8.73
2.66-2.58
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance(C.O.P)
Outdoor unit power supply
Capacity
NOTE: Test conditions are based on ISO 5151 (Refrigerant piping length (one way): 5m)
Cooling : Indoor DB27°C / WB19°C Heating : Indoor DB20°C
: Outdoor DB35°C / WB24°C : Outdoor DB 7°C / WB 6°C