EasyManua.ls Logo

Mitsubishi MSZ-GE60VA - SELECTING OPERATION MODES; Core Operation Modes

Mitsubishi MSZ-GE60VA
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Indoor model
MSZ-
GE22VA
MSZ-
GE25VA
MSZ-
GE35VA
MSZ-
GE42VA
MSZ-
GE50VA
MSZ-
GE60VA
MSZ-
GE71VA
Power supply Single phase 230 V, 50 Hz
Electrical
data
Power input
1
Cooling
W
22 29 43 38 58
Heating 23 30 39 62 58
Running
current
1
Cooling
A
0.22 0.29 0.39 0.35 0.51
Heating 0.23 0.31 0.36 0.53 0.51
Fan
motor
Model RC0J40-FK RC0J56-AF
Current 1
Cooling
A
0.22 0.29 0.39 0.35 0.51
Heating 0.23 0.31 0.36 0.53 0.51
Dimensions W × H × D mm 798 × 295 × 232 1100 × 325 × 238
Weight kg 10 16
Special remarks
Air direction 5
Air ow
Cooling
Super High
- 1,242 1,164
+ LONG + POWERFUL
Super High
m
3
/h
678 762 768 906 1,098 1,068
High 546
(552
2)
624 714 936 924
Med. 402
402
(414
2)
516 576 804 798
Low 288
(276
2)
288 408 468 678 690
Silent 246 348 390 588 582
Heating
Super High
- 1,242 1,164
+ LONG + POWERFUL
Super High
m
3
/h
690 786 870 1,098 1,068
High 546 624 732
936 (882 2)
924
Med. 396 402 516 576 804 798
Low 288
(276 2)
288 420 468 678 690
Silent 246 348 390 588 612
Sound level
Cooling
Super High
-5253
+ LONG + POWERFUL
Super High
dB(A)
42 43 46 49
High 36 40 44 45
Med. 29 30 35 38 41
Low 21 22 30 33 37
Silent 19 26 28 29 30
Heating
Super High
-52
+ LONG + POWERFUL
Super High
dB(A)
42 46 48 49
High 36 40 43 45
Med. 29 30 35 37 41
Low 21 22 30 33 37
Silent 19 26 28 29 30
Fan speed
Cooling
Super High
- 1,280 1,300
+ LONG + POWERFUL
Super High
rpm
1,020 1,120 1,120 1,280 1,090 1,140
High 860 950 1,060 960 1,010
Med. 670
670 (690 2)
810 890 850 900
Low 530 680 750 740 800
Silent 470 600
650 (690 2)
660 700
Heating
Super High
- 1,280 1,300
+ LONG + POWERFUL
Super High
rpm
1,040 1,140 1,240 1,090 1,140
High
860 (700
2)
950 (930 2)
1,080 (930 2)
960 (910 2)
1,010
Med.
670 (610
2)
810
890 (840 2)
850 900
Low 530 690 750 740 800
Silent 470 600 650 660 730
Fan speed regulator 5
Remote controller model KM09A SG10A
NOTE: Test conditions are based on ISO 5151.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor Dry-bulb temperature 20°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
1 Measured under rated operating frequency.
2 For multi system.
SPECIFICATION