EasyManua.ls Logo

Mitsubishi S16R2 Series - Storing Engine in Operable Condition

Mitsubishi S16R2 Series
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 LONG-TERM STORAGE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
183
Pub. No. K29001-00320 Revision: 1
9 Apply engine oil on the valve
mechanisms of all the cylinder
heads.
Tool: Oiler, oil jug, and others.
Fig. 9-2 Engine Oil - Apply (Valve Mechanism)
10 Install the rocker covers onto all the
cylinder heads.
Tool: Wrench
Fig. 9-3 Rocker Cover - Install
Restart
1 Pull the manual stop lever in the
direction to stop and hold the
position, and crank the engine for
approx. 10 seconds using the
starter.
Fig. 9-4 Restart after Storing
The location of the manual stop lever
varies depending on the specification
of the engine. Refer to
"Protection
System - Location" ( Page 82).
2 Pause for about 1 minute.
3 Repeat the operation of Step 1 and 2
for 2 or 3 times.
4 After starting the engine, check that
the engine oil pressure rises with a
pressure gauge.
5 Conduct a warm-up operation
"Warm-up Operation" ( Page 99) for
a sufficient duration to fully lubricate
all the components.
6 Apply load and increase the engine
speed to the rated speed.
Storing Engine in Operable
Condition
Perform maintenance operation "Maintenance
Operation" ( Page 103) once a month.