EasyManuals Logo

Mitsubishi VL-100U5-E User Manual

Mitsubishi VL-100U5-E
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Eng-2
English
-Electrical work must be done by
an electrical contractor (a licensed
electrician) in accordance with
the technical standards of the
equipment and local regulations
to ensure safety.
-%DGZLULQJDQGPLVWDNHVLQ
electrical work could result in
HOHFWULFVKRFNVRU¿UH
-Use circuit breakers connected
to the power supply to protect
against short circuits.*
1
-6KRUWFLUFXLWVFRXOGUHVXOWLQ¿UH
Caution
Install the unit only on a wall. Do
not install it on a ceiling.
-,QMXU\FRXOGUHVXOWLIWKHXQLWIDOOV
-Do not install the unit in
excessively hot areas (40°C or
PRUHQHDURSHQÀDPHVLQDUHDV
prone to oily smoke, or where
it could come in contact with
organic solvents.
-Fire could result.
-Always place a cover on the
terminal block after construction
work is complete.*
1
-Dust, humidity and the like could
FDXVHVKRUWFLUFXLWVRU¿UH
-Wear gloves when attaching the
unit.
-Failure to wear gloves could result
in injury.
Prohibited
You must
IROORZWKH
instructions
given.
-Attach the unit so that the air
supply/exhaust pipes slope
downward toward outdoors.
-Rainwater entering the unit could
UHVXOWLQHOHFWULFVKRFN¿UHRULQGRRU
items getting wet.
-Install the provided weather
covers.
-Rainwater entering the unit could
UHVXOWLQHOHFWULFVKRFN¿UHRULQGRRU
items getting wet.
-Be sure to shut off circuit
breakers or remove the power
plug from the wall outlet if the
Lossnay will not be used for a
long period after installation.
-Failure to do so could result in
HOHFWULFVKRFNIURPGHWHULRUDWHG
LQVXODWLRQRU¿UHIURPDVKRUWFLUFXLW
-When attaching the main unit
on the wall, press the main unit
against the wall and secure it
¿UPO\ZLWKWKHWZRVFUHZV
-7KHMRLQWJDSFRXOGFDXVHWKHZDOO
to become dirty.

9/(85(RQO\
Note
In mid-rise and high-rise buildings or in
coastal and other areas prone to strong
winds, wind could blow into the unit when it is
not operating. Install the Lossnay where it will
not be directly subject to wind.
Do not use the Lossnay in areas prone to
damage from salt or hot springs.
Dimensional outline drawing
12
226
106
ø150
26511
17
54
200
22
140
90
620
252
Exhaust
DLU¿OWHU
Air exhaust
hole
With panel open
Power cord (with plug)
9/85(RQO\
HIIHFWLYHOHQJWKDSSUR[P
Pull cord
9/85(RQO\
With panel
closed
Weather cover
Air supply/exhaust
pipe A
Air supply/exhaust
SLSH%
Louver
Lossnay
core (Heat
exchanger)
Outside air
Filter
Louver
(when vertical)
Louver
ZKHQKRUL]RQWDO
Shutter knob
(when shutter is
closed)
)DFWRU\GHIDXOW
Shutter knob
(when shutter
is open)
Indoor air
exhaust
hole
Wall
thickness
WR
Outside diameter ø75 mm x 2
Wall
thickness
WR
8QLWPP
Operating
indicator

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi VL-100U5-E and is the answer not in the manual?

Mitsubishi VL-100U5-E Specifications

General IconGeneral
BrandMitsubishi
ModelVL-100U5-E
CategoryFan
LanguageEnglish

Related product manuals