Eng-4
English
Mounting instructions
Wall-hole construction
'HWHUPLQHWKHLQVWDOODWLRQSRVLWLRQ

Make sure to allow the required clearances (at
OHDVWPPRQWRSPPWROHIWDQGULJKW
DQGPPRQERWWRPDURXQGWKHPRXQWLQJ
plate, as shown in the drawing below.
* Nothing should obstruct the
IURQWRIWKHXQLW'RQRWSODFH
DQ\WKLQJEORFNLQJDLUÀRZLQIURQW
RIWKH/RVVQD\
&KHFNWKDWWKHUHLQIRUFHPHQWLQVLGHZDOOLV
positioned properly to secure the mounting
SODWH,IWKHUHLVQRUHLQIRUFHPHQWEXLOGLQD
supporting structure.)
3) Place the mounting plate on the wall.
4) Attach the mounting plate loosely (with single
wood screw).
Note
Make sure that the mounting surface of the
PRXQWLQJSODWHLVÀDW
,ILWLVQRW/RVVQD\RSHUDWLRQFRXOGJHQHUDWH
noise or the shutter could not operate
properly.
2.
'HWHUPLQHWKHSRVLWLRQRIWKHZDOOKROHV
3RVLWLRQWKHZDOOKROHVDZD\IURPREVWUXFWLRQV
in the wall, within the ranges shown in the
mounting position diagram on page 3.
:RRGVFUHZIDVWHQORRVHO\
Mounting plate
5HLQIRUFHPHQW
At least
PP
At least
83 mm
At least
83 mm
At least
64 mm
3. Drill the wall holes.

5HPRYHWKHORRVHO\IDVWHQHGPRXQWLQJSODWH
/HDYHWKHZRRGVFUHZORRVHO\IDVWHQHGLQ
SURFHGXUHLQSODFH
'ULOOWKHZDOOKROHVRI¡WR¡PP
Note
Make the holes so they slope down as they
exit the outside wall.
7KLVLVQHFHVVDU\WRSUHYHQWWKHLQ¿OWUDWLRQRI
rainwater.
4. Pull out the power and connection
cables.
For VL-100EU
5-E only
'HWHUPLQHWKHSRZHUDQGFRQQHFWLRQFDEOH
SXOORXWORFDWLRQDQGPDNHDKROH6HHWKH
mounting position diagram on page 3.)
2) Pull out the power and connection cables on
the indoor side.
Note
For VL-100U5-E, install an electrical outlet
somewhere that the power cord plug can
reach. (The cord has an effective length of 3
m.)
'LDPHWHURIZDOO
hole
¡WR¡PP
Wall hole
Wall
OutsideInside
Power and
connection cables
3XOORXWSRVLWLRQ
Power and connection
cables