EasyManua.ls Logo

Molecular Devices SPECTRAmax PLUS 384 - User Manual

Molecular Devices SPECTRAmax PLUS 384
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPECTRAmax
®
PLUS
384
Microplate Spectrophotometer
Operators Manual
Molecular Devices Corporation
1311 Orleans Drive
Sunnyvale, California 94089
Part # 0112-0056
Rev. A

Other manuals for Molecular Devices SPECTRAmax PLUS 384

Questions and Answers

  • L
    lutztimothyAug 4, 2025
    What to do if Molecular Devices SPECTRAmax PLUS 384 does not turn on?
    • M
      Ms. Jane BurnsAug 4, 2025
      If your Molecular Devices Measuring Instruments isn't getting power (the LCD shows no display), ensure the power cord is securely plugged into both a functioning power outlet and the receptacle at the rear of the SPECTRAmax PLUS[384]. Also, verify that the power cord isn't loose or disconnected and that the power outlet is working correctly. If the issue persists, try replacing the fuses.
  • C
    cjohnstonAug 15, 2025
    How to manually open the drawer on Molecular Devices Measuring Instruments?
    • M
      Melissa LevyAug 15, 2025
      If the drawer on your Molecular Devices Measuring Instruments doesn't open, first, turn the instrument off and then on again. If the drawer remains closed, locate the groove in the upper left side wall of the door using your thumbnail, open the door, and pull the microplate drawer out of the instrument.
  • E
    Eric ClarkAug 23, 2025
    What to do if the drawer of my Molecular Devices Measuring Instruments does not open?
    • R
      Ray EvansAug 23, 2025
      If the drawer of your Molecular Devices Measuring Instruments does not open, try the following: * Turn the power to the instrument off and then on again. * Turn the incubator off (if it was on). * Power off the instrument, unplug the power cord, and use a blunt, flat object (like a spatula) to gently open the door. * Pull the plate drawer out of the instrument gently and remove the plate.

Summary

Instrument Description

Installation Procedures

Installation Safety Precautions

Critical safety warnings and cautions to follow before and during installation.

Stand-Alone Operation

Reading a Cuvette

Procedure for inserting a cuvette and acquiring reference/sample readings.

Maintenance and Troubleshooting

Technical Support and Safety

Contact information for support and general safety guidelines.

Replacing Fuses

Detailed guide on how to replace blown fuses in the instrument.

Error Codes and Diagnostics

Explains instrument error codes, messages, and their potential causes.

Molecular Devices SPECTRAmax PLUS 384 Specifications

General IconGeneral
TypeMicroplate Reader
Detection ModesAbsorbance
Light SourceXenon Flash Lamp
Bandwidth5 nm
Wavelength Repeatability± 0.2 nm
Pathlength CorrectionYes
Number of Channels1
SoftwareSoftMax Pro
Microplate Formats6-384 well plates
Wavelength Accuracy±2 nm
Dynamic Range0 - 4.0 OD
Absorbance Range0 - 4.0 OD