Performance Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
_100%safety factors built in for unmetered usage)
USEPA Influent
Parameter MCL Challenge Concentration
Chlorine
T&O -- --
Particulate** - _>10,000particles/mL
Parameter
Turbidity
Cysts
Asbestos
LeadatpH65
LeadatpH85
Hercuryat pH65
Hercuryat pH85
Alachlor
Undone
2,4@
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
Atrazine
USEPA
MCL
05 NTU
->99.95%Reduction
_>99%Reduction
0015 mg/L
0015 mg/L
0,002rng/L
0,002mg/L
0.002mg/L
0.0002rng/L
0.070mg/L
0,003mg/L
0,0% mg/L
0,040mg/L
0,075mg/L
0,003mg/L
Standard No. 42: Aesthetic Effects
Influent Effluent
Average Average Maximum
1,96mg/L 0,06mg/L 0,11mg/L
6,400,000#/mL 58,833#/mL 150,000#/mL
Standard No. 53:Health Effects
Influent
Challenge Concentration
1i+ 1 NTU***
Minimum50,000L
Influent
Average
10.5NTU
I18,750#/L
57 NF/L
0 1567 mg/L
01433 mg/L
00059 mg/L0006 my/L+ 10%
0.0367 mg/L
0.0020 mg/L
02033 mg/L
0,0160 mg/L
0.080 mg/L + 10% 0,0830 mg/L
0.2283 mg/L
0,0087 mg/L
Effluent
Average Maximum
0,1aNTU 028 NTU
<I#/L 4#/L
0996MF/L <i MF/L
<0.001mg/L <0001 mg/L
<0.001mg/L <0001 mg/L
0000350mg/L 00007mg/L
0000325mg/L 0.0006mg/L
0.00023mg/L 0.0004mg/L
<0.00002mg/L < 0.00002mg/L
0.00337mg/L 0.011000mg/L
0.00100mg/L 0.001000mg/L
0000500mg/L 0.000500mg/L
0 001000mg/L &001000mg/L
0000500mg/L 0.000500mg/L
<0.0005mg/L <0.0005mg/L
* Tested using a flow rote of 0.50 gpm; pressure of 60 psig; pH of 7,5 ± 0.5, tamp, of 68° ± 5°F (20° ± 3°C)
** Measurement in Portides/mL Particles used were 0,5-1 microns
*** NTU=Nephelometric Turbidity units
% Reduction Min.Required
Average Minimum Reduction
96#7% 9474% >50%
99.14% 9797% _>85%
% Reduction
Average Minimum
98,54% 9720%
>9999% >9999%
9960% 99,39%
9936% 9929%
9930% 9929%
94#0% 8750%
9320% 8929%
99,34% 9857%
99,00% 9&95%
98,32% 94,50%
93,44% 91,67%
96,51% 95,83%
98,78% 98,65%
99,78% 99,77%
9422% 93,33%
Min. Required
Reduction
05 NTU
->9995%
->99%
0010 mg/L
0010 mg/L
0,002 mg/L
0,002 mg/L
0,002 mg/L
0,0002 mg/L
0,070 mg/L
0,003 mg/L
0,005 mg/L
0,0a mg/L
0,075 mg/L
0,003 mg/L
Operating Specifications
* Capacitg: certified for up to 300 gallons (i135 I};up to one gear
t Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33-IO0°F (0.6-38°C)
Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when the indicator light flashes.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
Do not use with water that is microbiologicallg unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced bg this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
ChemicalUnit
ChlorineTasteand Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified by NSFInternational against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichiorobenzene and 2,4-D Reduction
Lead and Undone Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, RY40225
EPAEST No O70595-MN-001 27