SATELLITE
SYMPTOMS
1.
No
regulated
+9
volts
2.
Regulated
+9
volts
not
ad
justable.
3.
Excessive
ripple
on
+9
volts
PROBABLE
CAUSE
No
raw
DC
Load
exceeds
50
ma
Bad
regulator
Bad
regulator
Load
exceeds
50ma
Raw
DC
low
Excessive
ripple
on
raw
DC
CORRECTION
1.
Plug
and
line
cord
2.
Power
Switch
3.
Transformer
Tl
open
4.
Diodes
Dl
-
D4
open
5.
Filter
Caps
shortened
1.
Measure
resistance
of
+9
volts
to
qround
nominal
value
900
ohms
2.
Check
R2
fi
C3
1.
R
eplace
IC1
1.
Replace
ICl
2.
Check
R3,
R4,
R5
1.
Measure
resistance
of
+9
volts
to
ground
nominal
value
900
ohrr.s
2.
Check
R2
&
C3
1.
Transformer
Tl
2.
Diodes
Dl
-
D4
3.
Filter
Cap
1.
Filter
Caps
2.
Diodes
Dl
-
D4
3.
Transformer
Tl
4.
No
regulated
-9
volts
Bad
regulator
No
reference
No
raw
DC
Load
exceeds
50ma
V
1.
Replace
ICl
2.
Check
C3
1.
Check
+9
volts
1.
Transformer
Tl
2.
Diodes
Dl
-
D4
3.
Filter
caps
1.
Measure
resistance
of
-9
volts
to
ground
nominal
value
1000
ohms
2.
Check
C2