The text above the Potential / Actual bar will show the current state
of the system:
AutoWake Inactive: This will occur when:
AutoWake is turned off
Cruise setpoint is below 7mph or above 26mph, or
When actual speed is between 3mph and within 0.1mph of
setpoint.
Below 3mph, AutoWake will use static functionality. Within
0.1mph, AutoWake will use dynamic functionality. The 10 second
countdown timer will activate when actual speed is within 0.1 of
set speed AND when the boat slows down to less than 3mph. During this state, AutoWake
will do nothing.
Once the button is pressed to turn on AutoWake, the system will try to first fill to establish
the correct roll, then it will fill all the rear ballast until rear “Amplitude” is achieved. It does
this in Static mode when the boat is traveling less than 3 mph and in Dynamic mode when
the speed is within .1 of set speed. If AutoWake is active, achieved or in countdown, it will