2.Adjust Set Temperature: When screen is unlocked, press or
to display or adjust the set temperature.
3.Smart/Silence mode selection:
Smart mode as default will be activated when heat pump is on, and
screen shows .
Press to enter Silence mode, and screen shows .
(Smart mode: Unit will run from 20% to 100% / Silent mode: Unit will
run from 20% to 80%)
4.Defrosting
a. Auto Defrosting: When heat pump is defrosting, will be
flashing. After defrosting, will stop flashing.
b. Compulsory Defrosting: When heat pump is heating, press and
together for 5 seconds to start compulsory defrosting, and
will be flashing. After defrosting, will stop flashing.
(Note: Compulsory defrosting intervals should be more than 30 minutes
and the compressor should run for more than 10 minutes.)
5.Celsius & Fahrenheit
Unlock the screen and hold the and for 5 seconds to shift.