13
6.Heat/Cool (Only available for models with MICxxx codification)
Press to select mode:
a. Auto : adjustable temperature range 54~104
b. Heating : adjustable temperature range 64~104
c. Cooling : adjustable temperature range 54~86
VII. Testing
1.Inspection before use
A. Check installation of the entire heater and pipe connections
according to the pipe connecting drawing;
B. Check the electric wiring according to the electric wiring diagram;
and grounding connection;
C. Make sure that the main heater power switch is off;
D. Check the temperature setting;
E. Check the air inlet and outlet.
2.Trial
A. The user must start the water pump before the heat pump, and turn
off the heat pump before the water pump, or the heat pump could
be damaged;
B. The user should start the water pump, and check for any leakage
of water. Power the heat pump on by pressing the ON/OFF button
of the heat pump, and set suitable temperature in the thermostat.
C. In order to lower the electrical surcharge, the heater is equipped
with a timer delayed starting function. When starting the heater; the
fan will start 1 minute earlier than the compressor;
D. After the pool heat pump starts up, check for any abnormal noise
from the heater.