Features
technical
3
Technical data:
Models FEB-24ED
Category
II2H3P
Type
C12, C32, C42, C52, C82,
B22
Central heating performances Maximum
output
kW
23,7
kcal/h
20.382
Minimum
output
kW
7,6
kcal/h
6.536
Domestic hot water performances Maximum
output.
kW
23,7
kcal/h
20.382
Minimum
output
kW
7,6
kcal/h
6.536
Domestic hot water flow 25ºC increase (l/min)
13,6
Domestic hot water flow rate (l/min)
10
(34ºC increase)
Minimum flow rate for activating D.H.W. (l/min)
2
Operating pressure (bar) Maximun Central heating
3
Maximun D.H.W.
10
Minimum D.H.W.activation
0,3
Expansion vessel capacity (L)
7
Temperature selection range (ºC) Central heating
circuit
Floor Heating
40-60
Radiators
60-85
D.H.W.circuit
35-60
Gas inlet pressure (mbar) Natural G20
20
Propane G31
37
Gas consumption (Hi) Natural G20 (m³/h)
2,78
Propane G31 (kg/h)
2,1
Electrical suplly (V/Hz) 220-230V~50Hz
Max power consumption (W) 120
Dimensions (mm) Height 680
Width 390
Depth 250
Connections / Interior Ø in (mm) Gas Inlet ¾”/Ø18
Domestic cold water Inlet ½”/Ø15
Domestic hot water Outlet ½”/Ø15
Central heating Flow ¾”/Ø22
Central heating return ¾”/Ø22
Flue gas exit temperature (ºC) 140
Net weight (kg) 29
Gas type Natuaral G20 X
Propane G31 X
CE type examination certificate 99BN794
NOx (according to prNE483) 3
Degree protection IP-44
Directive 92/42/CEE
٭ ٭