EUP11
Instantaneous gas water heater
User, Installation and Maintenance Manual

Questions and Answers

  • R
    Richard BlackAug 1, 2025
    What to do if the Morco Water Heater burner does not switch off?
    • R
      Regina MarquezAug 1, 2025
      If the burner on your Morco Water Heater doesn't switch off when the water is turned off, it could be due to contamination on the gas valve seat, which requires testing and cleaning. Another potential cause is a gas valve push rod locked in the open position; in this case, check the cold water push rod's operation, and dis-assemble, clean, or replace if necessary. Also, check the gas pressure; if it exceeds the specified limit, replace the pressure regulator on the external bottle or tank.
  • T
    Tara RyanAug 5, 2025
    Why pilot on but the main burner does not ignite on my Morco EUP11 Water Heater?
    • T
      Tina StevensAug 5, 2025
      If the pilot light is on but the main burner of your Morco Water Heater doesn't ignite, the issue might be due to insufficient water pressure. Try to increase the external water supply pressure. Alternatively, the diaphragm could be broken, requiring a replacement.
  • J
    Jason WatsonAug 9, 2025
    How to fix Morco EUP11 when there is no spark?
    • D
      Donna AdamsAug 9, 2025
      If your Morco Water Heater isn't sparking, it could be due to a disconnected spark wire; reconnect it. Another possibility is a broken piezoelectric mechanism, which would need testing and replacement. Finally, the electrode might be damaged, and you would need to replace it.
  • C
    Carlos BrownAug 14, 2025
    What to do if the pilot does not stay on in Morco EUP11?
    • C
      Cindy TuckerAug 14, 2025
      If the pilot light on your Morco Water Heater doesn't stay on, it could be due to a faulty thermocouple, which would need replacing. Another potential cause is a broken magnetic valve, also requiring replacement.
  • T
    Tricia HendricksAug 17, 2025
    Why the pilot does not switch on when there is a spark in Morco EUP11 Water Heater?
    • R
      Robert CookAug 18, 2025
      If the pilot light on your Morco Water Heater doesn't switch on even when there's a spark, it could be due to a blocked pilot injector; clean it by immersing it in solvent or replace it. Another reason may be that the electrode activation position needs adjustment. Also ensure that there is a gas supply and open the appliance gas isolation valve. Finally, purge air from the gas tubes by turning on all gas rings on the hob for 30 seconds.
  • C
    Christie ArnoldAug 22, 2025
    Why the heat exchanger fins becomes sooty in a small amount of time in Morco EUP11?
    • C
      carolyndanielsAug 22, 2025
      The heat exchanger fins becoming sooty quickly in your Morco Water Heater can be caused by several factors. It may be due to poor draught, adverse weather conditions, or dusty surroundings; in this case, check the flue installation. A yellow flame could also be the culprit, so check the gas type and clean the burner. Finally, excess gas consumption might be the issue; check the gas pressure and adjust accordingly.
  • M
    Marie CampbellAug 27, 2025
    Why Morco Water Heater has a delayed burner activation?
    • X
      xjohnsonAug 27, 2025
      A delayed burner activation in your Morco Water Heater may occur if the pilot burner flame is too far from the main burner flame or if it is too short. To resolve this, check the inlet gas pressure and clean the injector and pilot burner.

Summary

GENERAL SAFETY WARNINGS

1. OPERATION

PRECAUTIONS TO BE TAKEN AGAINST FROST AND FREEZING CONDITIONS

3. INSTALLATION

3.a Regulations

Outlines regulations for LPG gas appliance installation.

3.d Gas Connection

Details on connecting the gas supply, valves, and pressure checks.

4. MAINTENANCE

4.b Troubleshooting: Problems and solutions

Common issues, causes, and solutions for appliance malfunctions.

FOR THE ENGINEER

STARTING UP THE APPLIANCE AND FINAL CHECKS

Procedures for initial appliance startup and final operational checks.

MINIMUM ANNUAL MAINTENANCE

WINTERISATION

Morco EUP11 Specifications

General IconGeneral
ModelEUP11
TypeInstantaneous Water Heater
IgnitionElectronic
Dimensions600 x 360 x 250 mm
Water Pressure (Max)10 bar
Fuel TypeLPG
Water Flow Rate11 L/min
Gas input24.7 kW
Water Pressure (Min)0.1 MPa
Flue Diameter100 mm