PLACEMENT & INSTALLATION OPERATING INSTRUCTIONS
STEP 4:
Place the exhaust pipe assembly (exhaust flat port) into the window sealing plate
assembly & tighten with screws.
INCORRECT INSTALLATION
Important! Keep the exhaust duct smooth. Incorrect
installation will affect work of the A/C.
Avoid bending or twisting the exhaust duct.
Ensure air can flow smoothly in the duct.
WARNING:
The exhaust duct is designed exclusively for this model.
Do not attempt to lengthen, modify or replace it as it will not work.
NOTE: Max. developed length of the exhaust duct is 1,500mm. It is recommended to
shorten it and keep it horizontal while installation.
REMOTE CONTROLLER
Install batteries into the remote control before first use:
Slide to open battery cover on the back of the remote control.
Insert 2 new AAA batteries into their proper (+) and (-) terminals
Slide back the battery cover into place.
NOTE:
Use only AAA batteries. Do not use rechargeable or other types of batteries.
Do not mix old and new batteries.
Remove batteries from the remote control if appliance is not to be used for a long time.
WARNING:
Never use leaked batteries.
Chemicals in batteries could result in such health hazards such as
burns. If battery liquids leak onto skin or clothes, wash with clean
water immediately. Rinse mouth immediately and consult a doctor if
batteries are swallowed.
n
ick
T
h
e
n
s
l
i
d
e
t
o
l
o
c
k
t
i
g
h
t
l
y
insert firstly
Bolt
COOLING MODE
Under cooling mode, cooling indicator will light on.
Temperature setting is from 16 C to 30 C.
Press Fan Speed Button to select from low/high fan speed.
FAN MODE
Under Fan mode, indicator will be on.
Press Fan Speed Button to select from low/ high fan speed.
Temperature cannot be set under Fan mode.
DRY MODE
Dry indicator will be on under this mode.
Remove water plug (see right), insert one end of pipe to
drainage hose and the other end into the water tank.
If ambient temperature ≥17ºC(or 62ºF)the compressor will
start and follow below sequence: if ambient temperature
≤15ºC (or 59ºF) the compressor will stop. When it reaches
≥17ºC, the compressor will start again (There would be a
3-min delay for Compressor protection).
Fan runs with a fixed low speed.
Temperature is fixed.
Notes: Under dry mode, dismantle the air exhaust duct or performance will be
affected and the water full alarm “FL” will sound.
TIMER MODE
In standby mode, press Timer button to set ON time. A range of 0 to 24 Hours could be
set by pressing on the UP/DOWN button. Timer indicator will light up in this mode.
In standby, press Timer button to set OFF time. A range of 0 to 24 Hours could be set by
pressing the UP/DOWN button. Timer indicator will light up in this mode.