Section 11 Trouble Shooting
Fault Reason Solution
Erratic register of Damaged roller surface Replace rubber rollers
the Creaser Check Gap Setting Reset & tighten to ensure rollers are driving card.
Faulty Drive motor Remove and replace motor assembly.
No Power Fuse Blown Replace with correct value.
or No Display Check Power supply input on
Check cables for continuity to
Emergency stop button.
Faulty wire or connection.
Check power supply output Black lead of meter to Black wire.
Voltage on CN2=5V dc R
Voltages should read 240V or 110VAC
Replace
ed lead of meter to Red wire.
Voltage on CN2=24V dc Red lead of meter to Yellow wire.
If supply has input but no output Replace PSU.
Check voltage on main If no voltage then check for damaged
PCB CN6 Brown and Blue wire or connection. Replace as required.
No Drive or Motors Pulsing Low or No Power to Motors Check green light is illuminated on both PSUs
Check 240/110VAC input to Large PSUs
( Meter across L & N terminals)
No LED on Stepper PCB Low or No Power from PSU Meter across V+ & V- of SP-150-24 reading 24V dc
Meter across V+ & V- of SP-150-48 reading 48V dc
Replace PSU if no or low reading
Meter across V+ of SP-150-48 & V- of SP-150-24 reading 72V dc
If voltage is correct but no light on stepper then check cable integrity.