Document No. 996-071, Revision: 1, Aug 99 © MORLEY-IAS
ZXa / Zxe
Commissioning Manual
ZXa
ZXe

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the MORLEY-IAS ZXe and is the answer not in the manual?

Summary

Introduction to ZX Fire Alarm Control Panels

Warnings and Cautions for Installation

Highlights safety procedures and operational precautions for installers, emphasizing adherence to regulations.

User Control Levels and Access

Controls and Displays on Fire Panels

Selecting the Commissioning Option

Steps to access the panel's commissioning functions, requiring Level 3 password entry.

Commissioning a New Fire Alarm System Installation

Step 1: General Setup Procedures

Initial steps including clearing configuration memory and checking factory default settings.

Step 2: Configuring Signaling Loops

Process for configuring loop devices, performing auto-learn, assigning zones, and entering descriptions.

Step 3: Configuring Peripherals

Steps for configuring peripheral devices, including auto-learn and device assignment.

Step 4: Configuring Sounders and Relays

Programming sounder patterns and relay operations based on zonal requirements.

Step 5: Configuring Day Mode Operation

Setting up delayed, sensitivity, or verification modes based on time of day.

Step 6: Configuring Network Options

Setting up panel addresses, slave panels, and network communication parameters.

Step 7: Commencing Normal Operation

Final checks including passwords, program integrity, and locking the memory.

Configure Option for Panel Programming

Accessing the Configure Option

Procedure to enter the main configuration menu, requiring the memory lock to be open.

Configuring Signaling Loops

Options for configuring signaling loops, including zones, devices, auto-learn, and calibration.

Auto Learn for Loop Devices

Facility to automatically detect and learn installed devices on a signaling loop.

Zone Assignment for Devices

Process for dividing the system into zones and assigning devices to specific zones.

Viewing and Editing Device Details

Accessing detailed information about devices on a loop and their configuration.

Changing Device Information Parameters

Modifying device settings such as sensor text, zone, and event assignments.

Editing Device Location Text

Procedure for entering or modifying the descriptive text for device locations.

Setting Alarm Thresholds (Device Sensitivity)

Adjusting pre-alarm and alarm levels for detectors, with day/night sensitivity options.

Peripheral Device Configuration

Auto Learn for Peripherals

Facility to automatically learn devices connected to the peripheral bus.

Sounder Configuration and Operation

Allocating Sounders and Ringing Patterns

Programming sounder operation relative to zones in alarm using predefined patterns.

Day Mode Operation Configuration

Commissioning Delayed Mode

Detailed steps for configuring delayed sounder and output activation based on time.

System Setup and Configuration

Network Configuration for Panel Systems

System Events and Logic Programming

Normal Operation and Supplementary Information

Commencing Normal Panel Operation

Steps to place the panel into its active operating state after configuration.

MORLEY-IAS ZXe Specifications

General IconGeneral
BrandMORLEY-IAS
ModelZXe
CategoryControl Panel
LanguageEnglish