After unpacking, the fire chamber should be unscrewed (where applicable) from the
wooden pallet and laid down carefully on its back. In order to avoid the stove and
the floor from being scratched, the cardboard wrapping may be used as a base. The
legs that come with the stove should be unpacked and screwed tightly onto the
cast base with the accompanying bolts (where applicable).
Carefully move the stove into position.
Because the stove is heavy, we recommend that this lifting is undertaken by two
people.
1.2 Building regulations1.2 Building regulations
1.2 Building regulations1.2 Building regulations
1.2 Building regulations
The stove installation and chimney construction must comply with the relevant
regulations as laid out in the current edition of Building Regulations.
Installing your stove is not normally a ‘do-it-yourself’ procedure. A fully competent
fitter should be consulted at all stages.
The following section contains the essential points.
1.3 Chimney sweep1.3 Chimney sweep
1.3 Chimney sweep1.3 Chimney sweep
1.3 Chimney sweep
It is always recommended that you consult a local chimney sweep prior to any in-
stallation to ensure that the chimney is in sound and clean condition. If the chim-
ney has not been in use for some time, it will need to be checked for cracks, birds’
nests etc before it is put back into service.
1.4 The stove’1.4 The stove’
1.4 The stove’1.4 The stove’
1.4 The stove’
s position/clearance rs position/clearance r
s position/clearance rs position/clearance r
s position/clearance r
equirequir
equirequir
equir
ementsements
ementsements
ements
A clearance requirement is only necessary when the stove is placed near combusti-
ble materials (wallpaper & plasterboard are considered as combustible surfaces).
When the walls are made of combustible material you must adhere to the clearance
chart below.
Stove typeStove type
Stove typeStove type
Stove type
Back of stove (A) Sides of stove (B) Distance to Furniture Back of stove (A) Sides of stove (B) Distance to Furniture
Back of stove (A) Sides of stove (B) Distance to Furniture Back of stove (A) Sides of stove (B) Distance to Furniture
Back of stove (A) Sides of stove (B) Distance to Furniture
Morsø 1410 150 mm 500 mm 850 mm
Morsø 1430 150 mm 500 mm 850 mm
Morsø 1440 150 mm 200 mm 800 mm
Morsø 1630 350 mm 600 mm 800 mm
Morsø 3110 400 mm 600 mm 800 mm
Morsø 3140 400 mm 450 mm 800 mm