EasyManua.ls Logo

Mosquito Magnet Commander - User Manual

Mosquito Magnet Commander
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For Outdoor Use Only
Commander
1440-680
Leader in 360º Customer Support
Customer Care Hotline:1-800-953-5737
Online Assistance Available
Certified Service Locations
Find out more at www.mosquitomagnet.com
!
Advanced Mosquito Defense Systems

Questions and Answers

  • S
    Sarah BeardJul 27, 2025
    Why won't my Mosquito Magnet Insect Control Equipment start?
    • C
      Cheryl MerrittJul 27, 2025
      If your Mosquito Magnet Insect Control Equipment won't start, stays not running, and the LCD LED shows a red light flashing every 7 seconds, it might be due to several reasons. First, check if the propane tank is empty by weighing it. If it's newly filled, it may need purging to remove air from the fuel line. Ensure all connections are secure and the propane tank valve is fully open. The fuel line might be blocked, the regulator not fully engaged, or the bug bag could be full or clogged, requiring replacement.
  • M
    Michael PattersonAug 2, 2025
    What does it mean when my Mosquito Magnet Insect Control Equipment flashes red and green?
    • N
      Natalie LaraAug 2, 2025
      If your Mosquito Magnet Insect Control Equipment shuts down and the LCD LED flashes red/green every 7 seconds, it indicates a high-temperature condition. Turn off the trap, allow it to cool for one hour, and then restart it. If the code continues, contact Customer Care at 1-877-224-1538.
  • A
    antonioodonnellAug 8, 2025
    What does a solid red light on my Mosquito Magnet Insect Control Equipment mean?
    • Z
      Zachary LarsonAug 8, 2025
      If your Mosquito Magnet Insect Control Equipment shuts down and the LED is solid red, it indicates an electrical fault. Contact Customer Care at 1-877-224-1538.
  • G
    Gerald GuzmanAug 14, 2025
    How to improve the catch rate of my Mosquito Magnet Insect Control Equipment?
    • M
      Mrs. Susan HarmonAug 14, 2025
      If you're experiencing low or no catch with your Mosquito Magnet Insect Control Equipment, ensure the temperature is consistently above 50°F (10°C), as insects may not be out yet. Review the trap placement guidelines in the owner’s manual. Operate the trap continuously, 24/7, for at least 4 weeks to disrupt mosquito reproductive cycles. Also, check for any restrictions to airflow, which may disrupt the counterflow.
  • G
    gpriceAug 20, 2025
    What does double red flashing on my Mosquito Magnet Insect Control Equipment mean?
    • D
      Daniel JonesAug 20, 2025
      If your Mosquito Magnet Insect Control Equipment shuts down and the LCD LED is double flashing red every 7 seconds, it indicates a thermistor fault. Contact Customer Care at: 1-877-224-1538.

Summary

Safety Instructions

General Safety Precautions

Important safety precautions and warnings for operating the trap.

Principal Parts

Parts Identification

Diagram and list of the main components of the Mosquito Magnet trap.

Assembly Instructions

Trap Assembly Procedure

Step-by-step instructions for assembling the Mosquito Magnet trap components.

Bug Bag Installation

Instructions for inserting the bug bag into the trap.

Set-Up

Charging Instructions

Steps for charging the rechargeable battery for the trap.

Trap Placement

Guidance on where to position the trap for optimal mosquito capture.

Propane Tank Installation

Instructions for connecting the propane tank to the trap.

Using the Correct Attractant

Information on selecting and using attractants for optimal trap performance.

R-Octenol Attractant Installation

Detailed steps for installing the R-Octenol attractant packet.

Instructions

Starting Instructions

Procedure for starting the Mosquito Magnet trap.

Shut Down Instructions

Procedure for safely shutting down the Mosquito Magnet trap.

When Not In Use & Storage

Guidance on storing the trap when not in use and end-of-season procedures.

Optimal Results

Recommendations for achieving optimal mosquito capture results.

Smart Technology

Setting Gas Saver Modes

How to configure and use gas saver modes to extend propane life.

Cold Temperature Shutdown

Explanation of the automatic shutdown feature in cold temperatures.

Low Battery & Child Safety Lock

Information on low battery warnings and the child safety lock function.

Maintenance

Propane Tank Changing Tips

Advice on correctly changing the propane tank for the trap.

Maintenance Schedule

A schedule outlining regular maintenance tasks for the trap.

Easy Quick Clear Valve

Using the Easy Quick Clear Valve

Step-by-step guide for operating the Easy Quick Clear Valve.

Troubleshooting

Common Problems and Solutions

Identifies common issues and provides solutions for the Mosquito Magnet trap.

Mosquito Magnet Commander Specifications

General IconGeneral
Coverage Area1 acre
Power SourcePropane
AttractantOctenol
Warranty1 year
FuelPropane
TypeInsect Trap