14
Maintenance
Maintenance
If using one of our Fuel-Saving Modes, be sure to adjust the dates on
the chart below.
21 Day Maintenance Cycle
- Rell propane. (Propane lasts approximately 21 days with
24-hour/7-days operation.)
- Replace short-range attractant cartridge.
See Mosquito Magnet
®
attractant label for instructions.
- Empty or replace bug bag.
Periodically wipe down the outside of the trap with clean water
and a damp cloth.
Charge your battery for 24 hours at the beginning of the season.
Propane Tank Changing Time
When attaching the regulator knob to a tank after a tank change,
be sure to fully tighten the regulator knob onto the tank. No need
to use tools, but do turn the knob as far as possible by hand. When
this is done, loosen the knob 1/4 turn, then re-tighten to maximize
seal.
The purpose for this is to fully engage the regulator onto the tank. If
the regulator is not fully engaged, the ow of gas may be restricted
to the point where the trap will show a gas empty code. If this
occurs, press the off button, close the tank valve, and remove the
regulator from the tank. Re-attach the regulator and try again.