8-8 Maintenance: Power Up Self-Test Error Codes
For LTR Models:
No Display improperly connected
display module or
damaged display
module.
check connection between main board and display module or
replace with new display module.
Table 8-3. Power Up Self-Test Error Codes (LTR Models)
If the error code
displayed is ...
Then, there is
a ...
To correct the problem ...
ESN BAD defective PTCB return to factory for PTCB replacement.
AppCode Fail defective PTCB
firmware
reflash PTCB firmware.
EER: Watchdog firmware failure restart radio
Unprogrammed programming error use CPS to properly program radio and PTCB.
ERROR: NO PTG no primary talk group use CPS to program zone with a Primary Talk Group.
Backdoor --- turn radio off and restart.
Table 8-2. Power Up Self-Test Error Codes (Continued)
If the error code
displayed is ...
Then, there is
a ...
To correct the problem ...