28 Rev. 12/2019
6.1 Possible Faults
Problem Possible cause Solution
The device cannot be
switched on.
The batteries are flat. Replace the batteries (see section
Changing the Battery on page 30).
The values measured
are much too high.
The switch for measuring range
selection is not correctly set.
Set the switch for measuring range
selection
to position (see
section Overview on page 18).
There is a malfunction in your
ignition system.
Carry out further tests on your
ignition system.
Incorrect values are
displayed.
The SparkScan1 high voltage
clamp is not correctly mounted
around the spark plug lead.
Clamp the high voltage clamp to a
spark plug lead in such a way that
it completely surrounds the spark
plug lead. The spark plug lead
must not exceed a maximum
diameter of 7 mm (0.27'').
The ambient temperature has
changed considerably.
Recalibrate the SparkView by
switching it off and on.
There is a malfunction in your
ignition system.
Carry out further tests on your
ignition system.