Movincool Classic Plus 26 Quick Start Guide

Movincool Classic Plus 26
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Accessory
Name*
Part Number
Ceiling Tile LA146373-8280
Self Supported
Duct
481744-0060
1
1
Accessory
Name*
Part Number
Ceiling Tile
LA146373-8280
Self Supported
Duct
481744-0060
2
2
Condenser Air
Plenum
LAY84270-0030 1
Condenser
Air
Plenum
QUICK START GUIDE
Classic Plus 26
• Moving the unit and installaon of cold air outlet ducts:
1 2
3
.
4
NEXT
PAGE
Refer to the operaon manual and pay aenon to all the warnings and cauons throughout the manual
Typical Installaon Opons
NOTE: Refer to the operaon manual for details on choosing the installaon site
A) Roll the unit into the space that needs cooling
1) Unlock the casters and move the MovinCool
unit to a flat, level surface and set the casters
back to the LOCKED posion.
B) OPTION 1 set up steps
• Warm air flange aachment to the unit:
1) Aach the warm air flange using the screws
included with it.
3) Place the duct over the flange on the top of the unit (see figure below).
• Warm air duct aachment to the ceiling le:
1) Holding the other end of the duct firmly about 1  away from the end, rotate the
end of the duct counterclockwise to decrease the diameter of the duct enough
to pass through the 12” hole in the ceiling le.
4) Again hold the duct firmly, about 1  away from the end over the flange
(see figure below).
5) Rotate the duct end counterclockwise unl the diameter reduces to an
appropriate size (see figure below).
2) Pass the duct through the 12” hole on the ceiling le (see figure below).
3) Repeat the step number 1) but this me rotate the end of the duct in clockwise
direcons unl duct diameter increases enough to lock inside the ceiling le (see
figure below).
• Removal of original ceiling le:
Remove the original selected ceiling le from the ceiling (if the le is 2’ x 4’, then cut
the le into 2’ x 2’ and place one piece back into the ceiling at the end).
• Installaon of the ceiling le with the duct:
Place the ceiling le (with the duct) inside the ceiling.
C) OPTION 2 set up steps
• Condenser Air Plenum Installaon:
1) Remove both of the filter frame assemblies from
the condenser side panel by liing them up and lng
outward at the boom as indicated by the arrows above.
2) Remove the filter elements from the filter frames
by pressing outward on the re-tainer at the indicated
points (A), then, opening the retainer (B).
(Save the filter frames for future use).
3) Temporairly remove the five (5) screws from the le side
of the rear panel.
(Save the screws for step 5 below).
4) Turn the latches of the Air Plenum counterclockwise
unl they stop. Place the Air Plenum over the
condenser openings and align the hinge/bracket
assembly mounng holes with the respecve screw
holes on the back of the unit.
5) For ease of installaon, turn the latches to the full clock-
wise posion. (This will hold the front part of the Plenum
onto the unit). Aach the hinge/bracket of the
Air Plenum to the rear of the unit using the original
five (5) screws that were temporarily removed in step 3.
Shrink
Ceiling Tile
Self
Supported
Duct
Self Supported Duct
Ceiling Tile
Warm Air
Flange Kit
481170-0191 1
Warm Air
Flange Kit
481170-0191 1
Unlocked
Locked
2) Install each cool air outlet duct using 4 screws
each as shown.
(2 cool air outlet ducts included with the unit).
• Warm air duct aachment to the unit:
1) Hold the duct firmly, about 1  away from the
end.
2) Rotate the end of the duct clockwise to increase
the duct diameter (see figure). This procedure
usually takes 2 people.
1 Foot
Expand
Hold Here
A
B
CONDITION TO USE OPTION 1
CONDITION TO USE OPTION 2
No negave air pressure** in the room
and the temperature of the infiltrated
air is below the room temperature.
Between 70
°F (21 °C) to 113 °F (45 °C)
Operang temperature Range:
Negave air pressure** in the room.
Between 70
°F (21 °C) to 113 °F (45 °C)
Operang temperature Range:
*Accessories Sold Separately
NOTE:
Ensure that the warm air moves away from the ceiling and the heat is dissipated.
If your applicaon does not meet this requirement, then extend the duct to the nearest
exhaust point based on the Maximum Equivalent Length listed in the operaon manual.
**The combinaon of the following could create negave air pressure:
-
MovinCool unit is installed and runs using OPTION 1.
-
Door to the room is closed.
-
No other source of air entering the room.

Other manuals for Movincool Classic Plus 26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Movincool Classic Plus 26 and is the answer not in the manual?

Movincool Classic Plus 26 Specifications

General IconGeneral
BrandMovincool
ModelClassic Plus 26
CategoryAir Conditioner
LanguageEnglish

Related product manuals